Skip to main content
Journal cover image

In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth.

Publication ,  Journal Article
Yao, J; Maslov, KI; Shi, Y; Taber, LA; Wang, LV
Published in: Optics letters
May 2010

A method is proposed to measure transverse blood flow by using photoacoustic Doppler broadening of bandwidth. By measuring bovine blood flowing through a plastic tube, the linear dependence of the broadening on the flow speed was validated. The blood flow of the microvasculature in a mouse ear and a chicken embryo (stage 16) was also studied.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Optics letters

DOI

EISSN

1539-4794

ISSN

0146-9592

Publication Date

May 2010

Volume

35

Issue

9

Start / End Page

1419 / 1421

Related Subject Headings

  • Ultrasonography, Doppler
  • Rheology
  • Regional Blood Flow
  • Optics and Photonics
  • Optics
  • Mice, Inbred Strains
  • Mice
  • Hemorheology
  • Ear
  • Chick Embryo
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Yao, J., Maslov, K. I., Shi, Y., Taber, L. A., & Wang, L. V. (2010). In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth. Optics Letters, 35(9), 1419–1421. https://doi.org/10.1364/ol.35.001419
Yao, Junjie, Konstantin I. Maslov, Yunfei Shi, Larry A. Taber, and Lihong V. Wang. “In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth.Optics Letters 35, no. 9 (May 2010): 1419–21. https://doi.org/10.1364/ol.35.001419.
Yao J, Maslov KI, Shi Y, Taber LA, Wang LV. In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth. Optics letters. 2010 May;35(9):1419–21.
Yao, Junjie, et al. “In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth.Optics Letters, vol. 35, no. 9, May 2010, pp. 1419–21. Epmc, doi:10.1364/ol.35.001419.
Yao J, Maslov KI, Shi Y, Taber LA, Wang LV. In vivo photoacoustic imaging of transverse blood flow by using Doppler broadening of bandwidth. Optics letters. 2010 May;35(9):1419–1421.
Journal cover image

Published In

Optics letters

DOI

EISSN

1539-4794

ISSN

0146-9592

Publication Date

May 2010

Volume

35

Issue

9

Start / End Page

1419 / 1421

Related Subject Headings

  • Ultrasonography, Doppler
  • Rheology
  • Regional Blood Flow
  • Optics and Photonics
  • Optics
  • Mice, Inbred Strains
  • Mice
  • Hemorheology
  • Ear
  • Chick Embryo