SU‐GG‐I‐154: Evaluation of Quantitative Potential of Breast Tomosynthesis Using a Voxelized Anthropomorphic Breast Phantom

Publication ,  Conference
Mehtaji, D; Shafer, C; Chen, B; lo, J
Published in: Medical Physics
January 1, 2010

Purpose: To assess the quantitative potential of breast tomosynthesis by estimating the percent density of voxelized anthropomorphic breast phantoms. Method and Materials: A Siemens breast tomosynthesis system was modeled using Monte Carlo methods and a voxelized anthropomorphic breast phantom. The images generated by the simulation were reconstructed using Siemens filtered back‐projection software. The non‐uniform background due to scatter, heel effect, and limited angular sampling was estimated by simulating and subtracting images of a uniform 100% fatty breast phantom. To estimate the density of each slice, the total number of fatty and glandular voxels was calculated both before and after applying a thresholding algorithm to classify voxels as fat vs. glandular. Finally, the estimated density of the reconstructed slice was compared to the known percent density of the corresponding slice from the voxelized phantom. This percent density estimation comparison was done for a 30%‐ and a 60%‐ dense 5cm breast phantom. Results: Without thresholding, overall density estimation errors for the central eleven slices were 0.64% and 2.1% for the 30% and 60% dense phantoms, respectively. After thresholding to classify voxels as fat vs. glandular, errors for central eleven were 3.5% and 6.2%, respectively. Voxel to voxel matching of the phantom vs. reconstructed slice demonstrated 80.3% and 73.08% respectively of voxels were correctly classified. Conclusion: The errors in slice density estimation were within 10% for both the phantoms thus implying that quantification of breast density using tomosynthesis is possible. However, limitations of the acquisition and reconstruction process continue to pose challenges in density estimation leading to potential voxel to voxel errors that warrant further investigation. Conflict of Interest:Joseph Lo: research grant and consultant, Siemens Healthcare. © 2010, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2010

Volume

37

Issue

6

Start / End Page

3137

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Mehtaji, D., Shafer, C., Chen, B., & lo, J. (2010). SU‐GG‐I‐154: Evaluation of Quantitative Potential of Breast Tomosynthesis Using a Voxelized Anthropomorphic Breast Phantom. In Medical Physics (Vol. 37, p. 3137). https://doi.org/10.1118/1.3468190
Mehtaji, D., C. Shafer, B. Chen, and J. lo. “SU‐GG‐I‐154: Evaluation of Quantitative Potential of Breast Tomosynthesis Using a Voxelized Anthropomorphic Breast Phantom.” In Medical Physics, 37:3137, 2010. https://doi.org/10.1118/1.3468190.
Mehtaji, D., et al. “SU‐GG‐I‐154: Evaluation of Quantitative Potential of Breast Tomosynthesis Using a Voxelized Anthropomorphic Breast Phantom.” Medical Physics, vol. 37, no. 6, 2010, p. 3137. Scopus, doi:10.1118/1.3468190.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2010

Volume

37

Issue

6

Start / End Page

3137

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences