SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product

Publication ,  Conference
Kim, S; Song, H; Samei, E; Yin, F; Yoshizumi, T
Published in: Medical Physics
January 1, 2010

Purpose: To characterize the cone‐beam CTDI (CBCTDI) and cone‐beam dose length product (CBDLP) by Monte Carlo (MC) technique. Method and Materials: An extended CT head phantom (60cm long) and an extended CT body phantom (90cm long) were created in our BEAMnrc/EGSnrc MC system to accurately model the CBCTDI. The CBCTDI is equivalent to CTDI except normalized with the actual beam width. Before the simulations, the beam width of a Varian OBI system was measured with radiochromic films. The MC model of the OBI x‐ray tube was used to acquire the phase space files of the full‐fan and half‐fan cone beams. Then, DOSXYZnrc user code simulated a total of twenty CBCT scans with the beam widths from 2cm to 13.6cm for the CT head phantom and from 2.2cm to 15.4cm for the CT body phantom. After the simulations, CBCT dose profiles at center and peripheries were extracted and integrated (dose profile integral, DPI) to calculate the CBCTDI per each beam width. The weighted CBCTDI (wCBCTDI) was calculated from DPI values by using 1/3 and 2/3 weighting equation and mean wCBCTDI was derived. Finally the CBDLP for each beam width was compared to each weighted DPI (wDPI) value. We also investigated the accuracy of the CBCTDI using the Dixon's point dose method. Results: Mean wCBCTDI was found as 8.590±0.010 cGy for head and 4.518±0.004 cGy for body scan. The CBDLP and wDPI was close within 0.3%. We also found that the point dose method can estimate the CBCTDI within 3% difference comparing to the DPI integration method. Conclusion: We proposed the CBCTDI and CBDLP concepts in CBCT dosimetry, validated the applicability of CBCTDI as a dose index for CBCT scan and demonstrated a clinically feasible to estimate the CBDLP using the point dose method. © 2010, American Association of Physicists in Medicine. All rights reserved.

Duke Scholars

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2010

Volume

37

Issue

6

Start / End Page

3104

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kim, S., Song, H., Samei, E., Yin, F., & Yoshizumi, T. (2010). SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product. In Medical Physics (Vol. 37, p. 3104). https://doi.org/10.1118/1.3468047
Kim, S., H. Song, E. Samei, F. Yin, and T. Yoshizumi. “SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product.” In Medical Physics, 37:3104, 2010. https://doi.org/10.1118/1.3468047.
Kim S, Song H, Samei E, Yin F, Yoshizumi T. SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product. In: Medical Physics. 2010. p. 3104.
Kim, S., et al. “SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product.” Medical Physics, vol. 37, no. 6, 2010, p. 3104. Scopus, doi:10.1118/1.3468047.
Kim S, Song H, Samei E, Yin F, Yoshizumi T. SU‐GG‐I‐14: A Method to Estimate Cone‐Beam CT Dose Index and Cone‐Beam Dose Length Product. Medical Physics. 2010. p. 3104.

Published In

Medical Physics

DOI

ISSN

0094-2405

Publication Date

January 1, 2010

Volume

37

Issue

6

Start / End Page

3104

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences