Skip to main content
Journal cover image

Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging.

Publication ,  Journal Article
Deng, Y; Palmeri, ML; Rouze, NC; Haystead, CM; Nightingale, KR
Published in: Ultrasound Med Biol
February 2018

Harmonic imaging techniques have been applied in ultrasonic elasticity imaging to obtain higher-quality tissue motion tracking data. However, harmonic tracking can be signal-to-noise ratio and penetration depth limited during clinical imaging, resulting in decreased yield of successful shear wave speed measurements. A logical approach is to increase the source pressure, but the in situ pressures used in diagnostic ultrasound have been subject to a de facto upper limit based on the Food and Drug Administration guideline for the mechanical index (MI <1.9). A recent American Institute of Ultrasound in Medicine report concluded that an in situ MI up to 4.0 could be warranted without concern for increased risk of cavitation in non-fetal tissues without gas bodies if there were a concurrent clinical benefit. This work evaluates the impact of using an elevated MI in harmonic motion tracking for hepatic shear wave elasticity imaging. The studies indicate that high-MI harmonic tracking increased shear wave speed estimation yield by 27% at a focal depth of 5 cm, with larger yield increase in more difficult-to-image patients. High-MI tracking improved harmonic tracking data quality by increasing the signal-to-noise ratio and decreasing jitter in the tissue motion data. We conclude that there is clinical benefit to use of elevated acoustic output in shear wave tracking, particularly in difficult-to-image patients.

Duke Scholars

Published In

Ultrasound Med Biol

DOI

EISSN

1879-291X

Publication Date

February 2018

Volume

44

Issue

2

Start / End Page

303 / 310

Location

England

Related Subject Headings

  • Signal-To-Noise Ratio
  • Image Processing, Computer-Assisted
  • Humans
  • Elasticity Imaging Techniques
  • Acoustics
  • Abdomen
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Deng, Y., Palmeri, M. L., Rouze, N. C., Haystead, C. M., & Nightingale, K. R. (2018). Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging. Ultrasound Med Biol, 44(2), 303–310. https://doi.org/10.1016/j.ultrasmedbio.2017.10.003
Deng, Yufeng, Mark L. Palmeri, Ned C. Rouze, Clare M. Haystead, and Kathryn R. Nightingale. “Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging.Ultrasound Med Biol 44, no. 2 (February 2018): 303–10. https://doi.org/10.1016/j.ultrasmedbio.2017.10.003.
Deng Y, Palmeri ML, Rouze NC, Haystead CM, Nightingale KR. Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging. Ultrasound Med Biol. 2018 Feb;44(2):303–10.
Deng, Yufeng, et al. “Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging.Ultrasound Med Biol, vol. 44, no. 2, Feb. 2018, pp. 303–10. Pubmed, doi:10.1016/j.ultrasmedbio.2017.10.003.
Deng Y, Palmeri ML, Rouze NC, Haystead CM, Nightingale KR. Evaluating the Benefit of Elevated Acoustic Output in Harmonic Motion Estimation in Ultrasonic Shear Wave Elasticity Imaging. Ultrasound Med Biol. 2018 Feb;44(2):303–310.
Journal cover image

Published In

Ultrasound Med Biol

DOI

EISSN

1879-291X

Publication Date

February 2018

Volume

44

Issue

2

Start / End Page

303 / 310

Location

England

Related Subject Headings

  • Signal-To-Noise Ratio
  • Image Processing, Computer-Assisted
  • Humans
  • Elasticity Imaging Techniques
  • Acoustics
  • Abdomen
  • 3202 Clinical sciences
  • 1103 Clinical Sciences