Exposures to lead-based paint dust in an inner-city high school

Publication ,  Journal Article
Decker, JA; Malkin, R; Kiefer, M
Published in: American Industrial Hygiene Association Journal
March 1, 1999

In response to concerns about lead-based paint (LBP) in an 85-year old high school, an evaluation was conducted to determine whether a lead exposure hazard existed for adult school staff. Deteriorating LBP was present on walls and ceilings throughout the school. At the time of the evaluation, abatement of LBP had been completed in approximately one-third of the school. One-hundred eighteen wipe samples for lead dust were collected from floors, teachers' desks, and interior window sills. Areas selected for sampling were based on the work location of the 45 participants providing blood for lead analysis. Wipe samples from hands were collected from all participants. The geometric means (GMs) for lead dust loadings on sills in unabated rooms (n=23) and abated rooms (n=16) were 342 and 102 μg/ft2, respectively. Nine sills in unabated rooms and one sill in an abated room exceeded the Housing and Urban Development (HUD) guidelines (500 μg/ft2lead) for residential housing following abatement activity. GMs for lead loadings on floors in unabated rooms (n=26) and abated rooms (n=14) were 136 and 70 μg/ft2lead, respectively. Seventeen floor samples from unabated rooms and 3 samples from abated rooms exceeded HUD guidelines (100 μg/ft2lead). The GM blood lead level (BLL) was 2.2 μg/dL (range: 0.6-5.6 μg/dL), similar to that of the general U.S. population. Despite peeling LBP and significant lead dust loadings, a hazard from LBP was not found for staff at the school. There were no relationships between surface lead and hand lead, BLL and abatement status of assigned work area, or BLL and hand lead.

Duke Scholars

Published In

American Industrial Hygiene Association Journal

ISSN

0002-8894

Publication Date

March 1, 1999

Volume

60

Issue

2

Start / End Page

191 / 194
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Decker, J. A., Malkin, R., & Kiefer, M. (1999). Exposures to lead-based paint dust in an inner-city high school. American Industrial Hygiene Association Journal, 60(2), 191–194.
Decker, J. A., R. Malkin, and M. Kiefer. “Exposures to lead-based paint dust in an inner-city high school.” American Industrial Hygiene Association Journal 60, no. 2 (March 1, 1999): 191–94.
Decker JA, Malkin R, Kiefer M. Exposures to lead-based paint dust in an inner-city high school. American Industrial Hygiene Association Journal. 1999 Mar 1;60(2):191–4.
Decker, J. A., et al. “Exposures to lead-based paint dust in an inner-city high school.” American Industrial Hygiene Association Journal, vol. 60, no. 2, Mar. 1999, pp. 191–94.
Decker JA, Malkin R, Kiefer M. Exposures to lead-based paint dust in an inner-city high school. American Industrial Hygiene Association Journal. 1999 Mar 1;60(2):191–194.

Published In

American Industrial Hygiene Association Journal

ISSN

0002-8894

Publication Date

March 1, 1999

Volume

60

Issue

2

Start / End Page

191 / 194