Skip to main content
Journal cover image

Scanning system for angle-resolved low-coherence interferometry.

Publication ,  Journal Article
Steelman, ZA; Ho, D; Chu, KK; Wax, A
Published in: Optics letters
November 2017

Angle-resolved low-coherence interferometry (a/LCI) detects precancer by enabling depth-resolved measurements of nuclear morphology in vivo. A significant limitation of a/LCI is the point-probe nature of the method, sampling <0.5  mm2 before probe relocation is necessary. In this work, we demonstrate a scanning method capable of assessing an area >100  mm2 without repositioning. By utilizing a reflection-only three-optic rotator prism and a two-axis scanning mirror, we demonstrate radial scans of a sample with a linear range of 12 mm and a full rotational range of 180°. Use of this design will improve the diagnostic utility of a/LCI for wide-area screening of tissue health.

Duke Scholars

Published In

Optics letters

DOI

EISSN

1539-4794

ISSN

0146-9592

Publication Date

November 2017

Volume

42

Issue

22

Start / End Page

4581 / 4584

Related Subject Headings

  • Phantoms, Imaging
  • Optics
  • Optical Devices
  • Interferometry
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
  • 0906 Electrical and Electronic Engineering
  • 0206 Quantum Physics
  • 0205 Optical Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Steelman, Z. A., Ho, D., Chu, K. K., & Wax, A. (2017). Scanning system for angle-resolved low-coherence interferometry. Optics Letters, 42(22), 4581–4584. https://doi.org/10.1364/ol.42.004581
Steelman, Zachary A., Derek Ho, Kengyeh K. Chu, and Adam Wax. “Scanning system for angle-resolved low-coherence interferometry.Optics Letters 42, no. 22 (November 2017): 4581–84. https://doi.org/10.1364/ol.42.004581.
Steelman ZA, Ho D, Chu KK, Wax A. Scanning system for angle-resolved low-coherence interferometry. Optics letters. 2017 Nov;42(22):4581–4.
Steelman, Zachary A., et al. “Scanning system for angle-resolved low-coherence interferometry.Optics Letters, vol. 42, no. 22, Nov. 2017, pp. 4581–84. Epmc, doi:10.1364/ol.42.004581.
Steelman ZA, Ho D, Chu KK, Wax A. Scanning system for angle-resolved low-coherence interferometry. Optics letters. 2017 Nov;42(22):4581–4584.
Journal cover image

Published In

Optics letters

DOI

EISSN

1539-4794

ISSN

0146-9592

Publication Date

November 2017

Volume

42

Issue

22

Start / End Page

4581 / 4584

Related Subject Headings

  • Phantoms, Imaging
  • Optics
  • Optical Devices
  • Interferometry
  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
  • 0906 Electrical and Electronic Engineering
  • 0206 Quantum Physics
  • 0205 Optical Physics