Scanning system for angle-resolved low-coherence interferometry.
Publication
, Journal Article
Steelman, ZA; Ho, D; Chu, KK; Wax, A
Published in: Optics letters
November 2017
Angle-resolved low-coherence interferometry (a/LCI) detects precancer by enabling depth-resolved measurements of nuclear morphology in vivo. A significant limitation of a/LCI is the point-probe nature of the method, sampling <0.5 mm2 before probe relocation is necessary. In this work, we demonstrate a scanning method capable of assessing an area >100 mm2 without repositioning. By utilizing a reflection-only three-optic rotator prism and a two-axis scanning mirror, we demonstrate radial scans of a sample with a linear range of 12 mm and a full rotational range of 180°. Use of this design will improve the diagnostic utility of a/LCI for wide-area screening of tissue health.
Duke Scholars
Published In
Optics letters
DOI
EISSN
1539-4794
ISSN
0146-9592
Publication Date
November 2017
Volume
42
Issue
22
Start / End Page
4581 / 4584
Related Subject Headings
- Phantoms, Imaging
- Optics
- Optical Devices
- Interferometry
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
- 0906 Electrical and Electronic Engineering
- 0206 Quantum Physics
- 0205 Optical Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Steelman, Z. A., Ho, D., Chu, K. K., & Wax, A. (2017). Scanning system for angle-resolved low-coherence interferometry. Optics Letters, 42(22), 4581–4584. https://doi.org/10.1364/ol.42.004581
Steelman, Zachary A., Derek Ho, Kengyeh K. Chu, and Adam Wax. “Scanning system for angle-resolved low-coherence interferometry.” Optics Letters 42, no. 22 (November 2017): 4581–84. https://doi.org/10.1364/ol.42.004581.
Steelman ZA, Ho D, Chu KK, Wax A. Scanning system for angle-resolved low-coherence interferometry. Optics letters. 2017 Nov;42(22):4581–4.
Steelman, Zachary A., et al. “Scanning system for angle-resolved low-coherence interferometry.” Optics Letters, vol. 42, no. 22, Nov. 2017, pp. 4581–84. Epmc, doi:10.1364/ol.42.004581.
Steelman ZA, Ho D, Chu KK, Wax A. Scanning system for angle-resolved low-coherence interferometry. Optics letters. 2017 Nov;42(22):4581–4584.
Published In
Optics letters
DOI
EISSN
1539-4794
ISSN
0146-9592
Publication Date
November 2017
Volume
42
Issue
22
Start / End Page
4581 / 4584
Related Subject Headings
- Phantoms, Imaging
- Optics
- Optical Devices
- Interferometry
- 5102 Atomic, molecular and optical physics
- 4009 Electronics, sensors and digital hardware
- 4006 Communications engineering
- 0906 Electrical and Electronic Engineering
- 0206 Quantum Physics
- 0205 Optical Physics