Skip to main content

Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses.

Publication ,  Conference
Helmer, KG; Chou, M-C; Preciado, RI; Gimi, B; Rollins, NK; Song, A; Turner, J; Mori, S
Published in: Proc SPIE Int Soc Opt Eng
February 27, 2016

It is now common for magnetic-resonance-imaging (MRI) based multi-site trials to include diffusion-weighted imaging (DWI) as part of the protocol. It is also common for these sites to possess MR scanners of different manufacturers, different software and hardware, and different software licenses. These differences mean that scanners may not be able to acquire data with the same number of gradient amplitude values and number of available gradient directions. Variability can also occur in achievable b-values and minimum echo times. The challenge of a multi-site study then, is to create a common protocol by understanding and then minimizing the effects of scanner variability and identifying reliable and accurate diffusion metrics. This study describes the effect of site, scanner vendor, field strength, and TE on two diffusion metrics: the first moment of the diffusion tensor field (mean diffusivity, MD), and the fractional anisotropy (FA) using two common analyses (region-of-interest and mean-bin value of whole brain histograms). The goal of the study was to identify sources of variability in diffusion-sensitized imaging and their influence on commonly reported metrics. The results demonstrate that the site, vendor, field strength, and echo time all contribute to variability in FA and MD, though to different extent. We conclude that characterization of the variability of DTI metrics due to site, vendor, field strength, and echo time is a worthwhile step in the construction of multi-center trials.

Duke Scholars

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

February 27, 2016

Volume

9788

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Helmer, K. G., Chou, M.-C., Preciado, R. I., Gimi, B., Rollins, N. K., Song, A., … Mori, S. (2016). Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses. In Proc SPIE Int Soc Opt Eng (Vol. 9788). United States. https://doi.org/10.1117/12.2217445
Helmer, K. G., M. -. C. Chou, R. I. Preciado, B. Gimi, N. K. Rollins, A. Song, J. Turner, and S. Mori. “Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses.” In Proc SPIE Int Soc Opt Eng, Vol. 9788, 2016. https://doi.org/10.1117/12.2217445.
Helmer KG, Chou M-C, Preciado RI, Gimi B, Rollins NK, Song A, et al. Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses. In: Proc SPIE Int Soc Opt Eng. 2016.
Helmer, K. G., et al. “Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses.Proc SPIE Int Soc Opt Eng, vol. 9788, 2016. Pubmed, doi:10.1117/12.2217445.
Helmer KG, Chou M-C, Preciado RI, Gimi B, Rollins NK, Song A, Turner J, Mori S. Multi-site study of diffusion metric variability: effects of site, vendor, field strength, and echo time on regions-of-interest and histogram-bin analyses. Proc SPIE Int Soc Opt Eng. 2016.

Published In

Proc SPIE Int Soc Opt Eng

DOI

ISSN

0277-786X

Publication Date

February 27, 2016

Volume

9788

Location

United States

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4009 Electronics, sensors and digital hardware
  • 4006 Communications engineering