We demonstrate the possibility of measuring FRET efficiency with a low-cost frequency-domain fluorescence lifetime imaging microscope (FD-FLIM). The system utilizes single-frequency-modulated excitation, which enables the use of cost-effective laser sources and electronics, simplification of data acquisition and analysis, and a dual-channel detection capability. Following calibration with coumarin 6, we measured the apparent donor lifetime in mTFP1-mVenus FRET standards expressed in living cells. We evaluated the system's sensitivity by differentiating the short and long lifetimes of mTFP1 corresponding to the known standards' high and low FRET efficiency, respectively. Furthermore, we show that the lifetime of the vinculin tension sensor, VinTS, at focal adhesions (2.30  ±  0.16  ns) is significantly (p  <  10  -  6) longer than the lifetime of the unloaded TSMod probe (2.02  ±  0.16  ns). The pixel dwell time was 6.8  μs for samples expressing the FRET standards, with signal typically an order of magnitude higher than VinTS. The apparent FRET efficiency () of the standards, calculated from the measured apparent lifetime, was linearly related to their known FRET efficiency by a factor of 0.92 to 0.99 (R2  =  0.98). This relationship serves as a calibration curve to convert apparent FRET to true FRET and circumvent the need to measure multiexponential lifetime decays. This approach yielded a FRET efficiency of 18% to 19.5%, for VinTS, in agreement with published values. Taken together, our results demonstrate a cost-effective, fast, and sensitive FD-FLIM approach with the potential to facilitate applications of FLIM in mechanobiology and FRET-based biosensing.

Duke Scholars

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

December 2019

Volume

24

Issue

12

Start / End Page

1 / 11

Related Subject Headings

  • Vinculin
  • Signal Processing, Computer-Assisted
  • Optics
  • Molecular Probes
  • Microscopy, Fluorescence
  • Mice
  • Image Processing, Computer-Assisted
  • Focal Adhesions
  • Fluorescence Resonance Energy Transfer
  • Equipment Design
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dumas, J.-P., Jiang, J. Y., Gates, E. M., Hoffman, B. D., Pierce, M. C., & Boustany, N. N. (2019). FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope. Journal of Biomedical Optics, 24(12), 1–11. https://doi.org/10.1117/1.jbo.24.12.126501
Dumas, John-Paul, James Y. Jiang, Evan M. Gates, Brenton D. Hoffman, Mark C. Pierce, and Nada N. Boustany. “FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope.Journal of Biomedical Optics 24, no. 12 (December 2019): 1–11. https://doi.org/10.1117/1.jbo.24.12.126501.
Dumas J-P, Jiang JY, Gates EM, Hoffman BD, Pierce MC, Boustany NN. FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope. Journal of biomedical optics. 2019 Dec;24(12):1–11.
Dumas, John-Paul, et al. “FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope.Journal of Biomedical Optics, vol. 24, no. 12, Dec. 2019, pp. 1–11. Epmc, doi:10.1117/1.jbo.24.12.126501.
Dumas J-P, Jiang JY, Gates EM, Hoffman BD, Pierce MC, Boustany NN. FRET efficiency measurement in a molecular tension probe with a low-cost frequency-domain fluorescence lifetime imaging microscope. Journal of biomedical optics. 2019 Dec;24(12):1–11.

Published In

Journal of biomedical optics

DOI

EISSN

1560-2281

ISSN

1083-3668

Publication Date

December 2019

Volume

24

Issue

12

Start / End Page

1 / 11

Related Subject Headings

  • Vinculin
  • Signal Processing, Computer-Assisted
  • Optics
  • Molecular Probes
  • Microscopy, Fluorescence
  • Mice
  • Image Processing, Computer-Assisted
  • Focal Adhesions
  • Fluorescence Resonance Energy Transfer
  • Equipment Design