Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.
Publication
, Journal Article
Song, G; Steelman, ZA; Kendall, W; Park, HS; Wax, A
Published in: Biomedical optics express
August 2020
Angle-resolved low-coherence interferometry (a/LCI) measures depth-resolved angular scattering for cell nuclear morphology analysis. 2D a/LCI, developed to collect across two scattering planes, is currently limited by the lack of spatial scanning. Here we demonstrate 2D a/LCI scanning across a three-dimensional volume using an image rotation scheme and a scanning mirror. Validation using various optical phantoms demonstrated excellent scatterer size determination over a 7.5 mm linear range, for a total accessible area of ∼44 mm2. Measurements from anisotropic scatterers allowed accurate determination of sizes and computation of aspect ratios. This scanning system will facilitate analysis of scatterer structure across wider tissue areas.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Biomedical optics express
DOI
EISSN
2156-7085
ISSN
2156-7085
Publication Date
August 2020
Volume
11
Issue
8
Start / End Page
4419 / 4430
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4003 Biomedical engineering
- 3212 Ophthalmology and optometry
- 0912 Materials Engineering
- 0205 Optical Physics
Citation
APA
Chicago
ICMJE
MLA
NLM
Song, G., Steelman, Z. A., Kendall, W., Park, H. S., & Wax, A. (2020). Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers. Biomedical Optics Express, 11(8), 4419–4430. https://doi.org/10.1364/boe.398052
Song, Ge, Zachary A. Steelman, Wesley Kendall, Han Sang Park, and Adam Wax. “Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.” Biomedical Optics Express 11, no. 8 (August 2020): 4419–30. https://doi.org/10.1364/boe.398052.
Song G, Steelman ZA, Kendall W, Park HS, Wax A. Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers. Biomedical optics express. 2020 Aug;11(8):4419–30.
Song, Ge, et al. “Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.” Biomedical Optics Express, vol. 11, no. 8, Aug. 2020, pp. 4419–30. Epmc, doi:10.1364/boe.398052.
Song G, Steelman ZA, Kendall W, Park HS, Wax A. Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers. Biomedical optics express. 2020 Aug;11(8):4419–4430.
Published In
Biomedical optics express
DOI
EISSN
2156-7085
ISSN
2156-7085
Publication Date
August 2020
Volume
11
Issue
8
Start / End Page
4419 / 4430
Related Subject Headings
- 5102 Atomic, molecular and optical physics
- 4003 Biomedical engineering
- 3212 Ophthalmology and optometry
- 0912 Materials Engineering
- 0205 Optical Physics