Skip to main content
Journal cover image

Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.

Publication ,  Journal Article
Song, G; Steelman, ZA; Kendall, W; Park, HS; Wax, A
Published in: Biomedical optics express
August 2020

Angle-resolved low-coherence interferometry (a/LCI) measures depth-resolved angular scattering for cell nuclear morphology analysis. 2D a/LCI, developed to collect across two scattering planes, is currently limited by the lack of spatial scanning. Here we demonstrate 2D a/LCI scanning across a three-dimensional volume using an image rotation scheme and a scanning mirror. Validation using various optical phantoms demonstrated excellent scatterer size determination over a 7.5 mm linear range, for a total accessible area of ∼44 mm2. Measurements from anisotropic scatterers allowed accurate determination of sizes and computation of aspect ratios. This scanning system will facilitate analysis of scatterer structure across wider tissue areas.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Biomedical optics express

DOI

EISSN

2156-7085

ISSN

2156-7085

Publication Date

August 2020

Volume

11

Issue

8

Start / End Page

4419 / 4430

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4003 Biomedical engineering
  • 3212 Ophthalmology and optometry
  • 0912 Materials Engineering
  • 0205 Optical Physics
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Song, G., Steelman, Z. A., Kendall, W., Park, H. S., & Wax, A. (2020). Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers. Biomedical Optics Express, 11(8), 4419–4430. https://doi.org/10.1364/boe.398052
Song, Ge, Zachary A. Steelman, Wesley Kendall, Han Sang Park, and Adam Wax. “Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.Biomedical Optics Express 11, no. 8 (August 2020): 4419–30. https://doi.org/10.1364/boe.398052.
Song G, Steelman ZA, Kendall W, Park HS, Wax A. Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers. Biomedical optics express. 2020 Aug;11(8):4419–30.
Song, Ge, et al. “Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers.Biomedical Optics Express, vol. 11, no. 8, Aug. 2020, pp. 4419–30. Epmc, doi:10.1364/boe.398052.
Song G, Steelman ZA, Kendall W, Park HS, Wax A. Spatial scanning of a sample with two-dimensional angle-resolved low-coherence interferometry for analysis of anisotropic scatterers. Biomedical optics express. 2020 Aug;11(8):4419–4430.
Journal cover image

Published In

Biomedical optics express

DOI

EISSN

2156-7085

ISSN

2156-7085

Publication Date

August 2020

Volume

11

Issue

8

Start / End Page

4419 / 4430

Related Subject Headings

  • 5102 Atomic, molecular and optical physics
  • 4003 Biomedical engineering
  • 3212 Ophthalmology and optometry
  • 0912 Materials Engineering
  • 0205 Optical Physics