Skip to main content

Practice 'safe scans': why ultrasound transducer covers should be considered best practice.

Publication ,  Journal Article
Prinzbach, A; Gadsden, J
Published in: Reg Anesth Pain Med
June 10, 2025

Single-injection, ultrasound-guided nerve block procedures involve puncturing the skin in close proximity to an ultrasound transducer, creating a potential vector for transmission of microbial organisms when skin flora and blood come into contact with the probe. Practice patterns regarding disinfection of the transducer and the use of barrier protection are inconsistent, ranging from sterile sleeve probe covers to no cover at all. Although sleeve probe covers are easy and straightforward to use and serve to protect patients, providers and medical equipment, their utilisation remains controversial. Standardisation of their use eliminates the impact of improper or haphazard probe disinfection and makes infection control practices consistent and reproducible. This position is shared by multiple societies and authorities on ultrasound and acute care medicine. In this Daring Discourse, we outline the arguments supporting the utilisation of single-use sleeve probe covers to ensure patient safety with respect to vector-borne transmission of microbes during single-injection regional anaesthesia procedures.

Duke Scholars

Published In

Reg Anesth Pain Med

DOI

EISSN

1532-8651

Publication Date

June 10, 2025

Volume

50

Issue

6

Start / End Page

523 / 525

Location

England

Related Subject Headings

  • Ultrasonography, Interventional
  • Transducers
  • Patient Safety
  • Nerve Block
  • Infection Control
  • Humans
  • Equipment Design
  • Equipment Contamination
  • Disinfection
  • Anesthesiology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Prinzbach, A., & Gadsden, J. (2025). Practice 'safe scans': why ultrasound transducer covers should be considered best practice. Reg Anesth Pain Med, 50(6), 523–525. https://doi.org/10.1136/rapm-2024-105655
Prinzbach, Ariana, and Jeffrey Gadsden. “Practice 'safe scans': why ultrasound transducer covers should be considered best practice.Reg Anesth Pain Med 50, no. 6 (June 10, 2025): 523–25. https://doi.org/10.1136/rapm-2024-105655.
Prinzbach A, Gadsden J. Practice 'safe scans': why ultrasound transducer covers should be considered best practice. Reg Anesth Pain Med. 2025 Jun 10;50(6):523–5.
Prinzbach, Ariana, and Jeffrey Gadsden. “Practice 'safe scans': why ultrasound transducer covers should be considered best practice.Reg Anesth Pain Med, vol. 50, no. 6, June 2025, pp. 523–25. Pubmed, doi:10.1136/rapm-2024-105655.
Prinzbach A, Gadsden J. Practice 'safe scans': why ultrasound transducer covers should be considered best practice. Reg Anesth Pain Med. 2025 Jun 10;50(6):523–525.

Published In

Reg Anesth Pain Med

DOI

EISSN

1532-8651

Publication Date

June 10, 2025

Volume

50

Issue

6

Start / End Page

523 / 525

Location

England

Related Subject Headings

  • Ultrasonography, Interventional
  • Transducers
  • Patient Safety
  • Nerve Block
  • Infection Control
  • Humans
  • Equipment Design
  • Equipment Contamination
  • Disinfection
  • Anesthesiology