Skip to main content

Comb-push Ultrasound Shear Elastography (CUSE): A novel and fast technique for shear elasticity imaging

Publication ,  Conference
Song, P; Urban, MW; Manduca, A; Zhao, H; Greenleaf, JF; Chen, S
Published in: IEEE International Ultrasonics Symposium, IUS
December 1, 2012

Multiple push-detect acquisitions are typically required in current acoustic radiation force based shear wave elasticity imaging methods to reconstruct a full FOV elasticity map, which can result in potential motion artifacts and difficulties in studying tissue dynamic mechanical properties. Comb-push Ultrasound Shear Elastography (CUSE) is a novel and fast shear elasticity imaging technique which utilizes the comb-push to produce a complex shear wave field with shear waves propagating through all imaging pixels so that a full FOV shear elasticity map can be reconstructed with only one rapid data acquisition (less than 25 ms). Three versions of CUSE are presented in this paper: Unfocused CUSE (U-CUSE), Focused CUSE (F-CUSE), and Marching CUSE (M-CUSE). Homogeneous and inclusion phantom experiments showed that all CUSE methods produced accurate and smooth shear elasticity maps with excellent contrast between the inclusion and background. Comparable elasticity maps to Supersonic Shear Imaging (SSI) could be obtained using CUSE, with low MI and heating. Finally, the feasibility of using CUSE in clinical studies was demonstrated by promising results from preliminary in vivo case studies on human biceps muscle, thyroid, breast and liver. © 2012 IEEE.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE International Ultrasonics Symposium, IUS

DOI

EISSN

1948-5727

ISSN

1948-5719

Publication Date

December 1, 2012

Start / End Page

1842 / 1845
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Song, P., Urban, M. W., Manduca, A., Zhao, H., Greenleaf, J. F., & Chen, S. (2012). Comb-push Ultrasound Shear Elastography (CUSE): A novel and fast technique for shear elasticity imaging. In IEEE International Ultrasonics Symposium, IUS (pp. 1842–1845). https://doi.org/10.1109/ULTSYM.2012.0462
Song, P., M. W. Urban, A. Manduca, H. Zhao, J. F. Greenleaf, and S. Chen. “Comb-push Ultrasound Shear Elastography (CUSE): A novel and fast technique for shear elasticity imaging.” In IEEE International Ultrasonics Symposium, IUS, 1842–45, 2012. https://doi.org/10.1109/ULTSYM.2012.0462.
Song P, Urban MW, Manduca A, Zhao H, Greenleaf JF, Chen S. Comb-push Ultrasound Shear Elastography (CUSE): A novel and fast technique for shear elasticity imaging. In: IEEE International Ultrasonics Symposium, IUS. 2012. p. 1842–5.
Song, P., et al. “Comb-push Ultrasound Shear Elastography (CUSE): A novel and fast technique for shear elasticity imaging.” IEEE International Ultrasonics Symposium, IUS, 2012, pp. 1842–45. Scopus, doi:10.1109/ULTSYM.2012.0462.
Song P, Urban MW, Manduca A, Zhao H, Greenleaf JF, Chen S. Comb-push Ultrasound Shear Elastography (CUSE): A novel and fast technique for shear elasticity imaging. IEEE International Ultrasonics Symposium, IUS. 2012. p. 1842–1845.

Published In

IEEE International Ultrasonics Symposium, IUS

DOI

EISSN

1948-5727

ISSN

1948-5719

Publication Date

December 1, 2012

Start / End Page

1842 / 1845