A simple method to measure mesenteric arteriovenous shunt flow during arteriography.

Publication ,  Journal Article
Barth, KH; Mitchell, TG; Groves, TF; Starr, FL; Kasecamp, WR; White, RI
Published in: Investigative radiology
1978

A quantitative method for external detection of mesenteric arteriovenous shunts was developed. 99mTc-Human Serum Albumin Microspheres (15--30 microns) were injected into the superior mesenteric artery of dogs through an angiographic catheter, followed by external scintillation counting of the liver activity, which represented the shunted spheres. Thereafter, 99mTc-sulfur colloid was injected identically and the liver activity counted again. The liver net count after sulfur colloid represented a 100% shunt, when a correction factor for the actual liver uptake was applied. The a shunt rate was calculated. Eleven animal studies were performed and shunt rates similar to previous in vitro determinations were obtained. This method is suitable for clinical investigation and can conveniently be applied to mesenteric arteriography.

Duke Scholars

Published In

Investigative radiology

ISSN

0020-9996

Publication Date

1978

Volume

13

Issue

3

Start / End Page

191 / 194

Location

united states

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Barth, K. H., Mitchell, T. G., Groves, T. F., Starr, F. L., Kasecamp, W. R., & White, R. I. (1978). A simple method to measure mesenteric arteriovenous shunt flow during arteriography. Investigative Radiology, 13(3), 191–194.
Barth, K. H., T. G. Mitchell, T. F. Groves, F. L. Starr, W. R. Kasecamp, and R. I. White. “A simple method to measure mesenteric arteriovenous shunt flow during arteriography.Investigative Radiology 13, no. 3 (1978): 191–94.
Barth KH, Mitchell TG, Groves TF, Starr FL, Kasecamp WR, White RI. A simple method to measure mesenteric arteriovenous shunt flow during arteriography. Investigative radiology. 1978;13(3):191–4.
Barth, K. H., et al. “A simple method to measure mesenteric arteriovenous shunt flow during arteriography.Investigative Radiology, vol. 13, no. 3, 1978, pp. 191–94.
Barth KH, Mitchell TG, Groves TF, Starr FL, Kasecamp WR, White RI. A simple method to measure mesenteric arteriovenous shunt flow during arteriography. Investigative radiology. 1978;13(3):191–194.

Published In

Investigative radiology

ISSN

0020-9996

Publication Date

1978

Volume

13

Issue

3

Start / End Page

191 / 194

Location

united states

Related Subject Headings

  • Nuclear Medicine & Medical Imaging
  • 1103 Clinical Sciences