Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel
Journal cover image

Comparison of the ACL and ACL graft forces before and after ACL reconstruction: an in-vitro robotic investigation.

Publication ,  Journal Article
Li, G; Papannagari, R; DeFrate, LE; Yoo, JD; Park, SE; Gill, TJ
Published in: Acta Orthop
April 2006

BACKGROUND: Long-term follow-up studies have indicated that there is an increased incidence of arthrosis following anterior cruciate ligament (ACL) reconstruction, suggesting that the reconstruction may not reproduce intact ACL biomechanics. We studied not only the magnitude but also the orientation of the ACL and ACL graft forces. METHODS: 10 knee specimens were tested on a robotic testing system with the ACL intact, deficient, and reconstructed (using a bone-patella tendon-bone graft). The magnitude and orientation of the ACL and ACL graft forces were determined under an anterior tibial load of 130 N at full extension, and 15, 30, 60, and 90 degrees of flexion. Orientation was described using elevation angle (the angle formed with the tibial plateau in the sagittal plane) and deviation angle (the angle formed with respect to the anteroposterior direction in the transverse plane). RESULTS: ACL reconstruction restored anterior tibial translation to within 2.6 mm of that of the intact knee under the 130-N anterior load. Average internal tibial rotation was reduced after ACL reconstruction at all flexion angles. The force vector of the ACL graft was significantly different from the ACL force vector. The average values of the elevation and deviation angles of the ACL graft forces were higher than that of the intact ACL at all flexion angles. INTERPRETATION: Contemporary single bundle ACL reconstruction restores anterior tibial translation under anterior tibial load with different forces (both magnitude and orientation) in the graft compared to the intact ACL. Such graft function might alter knee kinematics in other degrees of freedom and could overly constrain the tibial rotation. An anatomic ACL reconstruction should reproduce the magnitude and orientation of the intact ACL force vector, so that the 6-degrees-of-freedom knee kinematics and joint reaction forces can be restored.

Duke Scholars

Published In

Acta Orthop

DOI

ISSN

1745-3674

Publication Date

April 2006

Volume

77

Issue

2

Start / End Page

267 / 274

Location

Sweden

Related Subject Headings

  • Robotics
  • Range of Motion, Articular
  • Plastic Surgery Procedures
  • Osteoarthritis, Knee
  • Orthopedics
  • Middle Aged
  • In Vitro Techniques
  • Humans
  • Cadaver
  • Bone Transplantation
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Li, G., Papannagari, R., DeFrate, L. E., Yoo, J. D., Park, S. E., & Gill, T. J. (2006). Comparison of the ACL and ACL graft forces before and after ACL reconstruction: an in-vitro robotic investigation. Acta Orthop, 77(2), 267–274. https://doi.org/10.1080/17453670610046019
Li, Guoan, Ramprasad Papannagari, Louis E. DeFrate, Jae Doo Yoo, Sang Eun Park, and Thomas J. Gill. “Comparison of the ACL and ACL graft forces before and after ACL reconstruction: an in-vitro robotic investigation.Acta Orthop 77, no. 2 (April 2006): 267–74. https://doi.org/10.1080/17453670610046019.
Li G, Papannagari R, DeFrate LE, Yoo JD, Park SE, Gill TJ. Comparison of the ACL and ACL graft forces before and after ACL reconstruction: an in-vitro robotic investigation. Acta Orthop. 2006 Apr;77(2):267–74.
Li, Guoan, et al. “Comparison of the ACL and ACL graft forces before and after ACL reconstruction: an in-vitro robotic investigation.Acta Orthop, vol. 77, no. 2, Apr. 2006, pp. 267–74. Pubmed, doi:10.1080/17453670610046019.
Li G, Papannagari R, DeFrate LE, Yoo JD, Park SE, Gill TJ. Comparison of the ACL and ACL graft forces before and after ACL reconstruction: an in-vitro robotic investigation. Acta Orthop. 2006 Apr;77(2):267–274.
Journal cover image

Published In

Acta Orthop

DOI

ISSN

1745-3674

Publication Date

April 2006

Volume

77

Issue

2

Start / End Page

267 / 274

Location

Sweden

Related Subject Headings

  • Robotics
  • Range of Motion, Articular
  • Plastic Surgery Procedures
  • Osteoarthritis, Knee
  • Orthopedics
  • Middle Aged
  • In Vitro Techniques
  • Humans
  • Cadaver
  • Bone Transplantation