Skip to main content

Behavioral modeling and performance evaluation of microelectrofluidics- based PCR systems using systemC

Publication ,  Journal Article
Zhang, T; Chakrabarty, K; Fair, RB
Published in: IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems
2004

Composite microsystems that incorporate microelectromechanical and microelectrofluidic devices are emerging as the next generation of system-on-a-chip (SOC). We present a performance comparison between two types of microelectrofluidic systems (MEFS): continuous-flow systems and droplet-based systems. The comparison is based on a specific microelectrofluidic application - a polymerase chain reaction (PCR) system. The behavioral modeling, simulation, and performance evaluation are based on a SystemC design environment. The performance comparison includes the system throughput, system-correction capacity, system-processing capacity, and system-design complexity. By using our system-performance evaluation environment, we demonstrated that the droplet-based MEFS provides higher performance, as well as lower design and integration complexity.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems

DOI

Publication Date

2004

Volume

23

Issue

6

Start / End Page

843 / 858

Related Subject Headings

  • Computer Hardware & Architecture
  • 4607 Graphics, augmented reality and games
  • 4009 Electronics, sensors and digital hardware
  • 1006 Computer Hardware
  • 0906 Electrical and Electronic Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, T., Chakrabarty, K., & Fair, R. B. (2004). Behavioral modeling and performance evaluation of microelectrofluidics- based PCR systems using systemC. IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems, 23(6), 843–858. https://doi.org/10.1109/TCAD.2004.828115
Zhang, Tianhao, Krishnendu Chakrabarty, and Richard B. Fair. “Behavioral modeling and performance evaluation of microelectrofluidics- based PCR systems using systemC.” IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems 23, no. 6 (2004): 843–58. https://doi.org/10.1109/TCAD.2004.828115.
Zhang T, Chakrabarty K, Fair RB. Behavioral modeling and performance evaluation of microelectrofluidics- based PCR systems using systemC. IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems. 2004;23(6):843–58.
Zhang, Tianhao, et al. “Behavioral modeling and performance evaluation of microelectrofluidics- based PCR systems using systemC.” IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems, vol. 23, no. 6, 2004, pp. 843–58. Manual, doi:10.1109/TCAD.2004.828115.
Zhang T, Chakrabarty K, Fair RB. Behavioral modeling and performance evaluation of microelectrofluidics- based PCR systems using systemC. IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems. 2004;23(6):843–858.

Published In

IEEE Transactions on Computer-Aided Design of Integrated Circuits and Systems

DOI

Publication Date

2004

Volume

23

Issue

6

Start / End Page

843 / 858

Related Subject Headings

  • Computer Hardware & Architecture
  • 4607 Graphics, augmented reality and games
  • 4009 Electronics, sensors and digital hardware
  • 1006 Computer Hardware
  • 0906 Electrical and Electronic Engineering