Physical characterization of a prototype selenium-based full field digital mammography detector.

Publication ,  Journal Article
Saunders, RS; Samei, E; Jesneck, JL; Lo, JY
Published in: Med Phys
February 2005

The purpose of this study was to measure experimentally the physical performance of a prototype mammographic imager based on a direct detection, flat-panel array design employing an amorphous selenium converter with 70 microm pixels. The system was characterized for two different anode types, a molybdenum target with molybdenum filtration (Mo/Mo) and a tungsten target with rhodium filtration (W/Rh), at two different energies, 28 and 35 kVp, with approximately 2 mm added aluminum filtration. To measure the resolution, the presampled modulation transfer function (MTF) was measured using an edge method. The normalized noise power spectrum (NNPS) was measured by two-dimensional Fourier analysis of uniformly exposed mammograms. The detective quantum efficiencies (DQEs) were computed from the MTFs, the NNPSs, and theoretical ideal signal to noise ratios. The MTF was found to be close to its ideal limit and reached 0.2 at 11.8 mm(-1) and 0.1 at 14.1 mm(-1) for images acquired at an RQA-M2 technique (Mo/Mo anode, 28 kVp, 2 mm Al). Using a tungsten technique (MW2; W/Rh anode, 28 kVp, 2 mm Al), the MTF went to 0.2 at 11.2 mm(-1) and to 0.1 at 13.3 mm(-1). The DQE reached a maximum value of 54% at 1.35 mm(-1) for the RQA-M2 technique at 1.6 microC/kg and achieved a peak value of 64% at 1.75 mm(-1) for the tungsten technique (MW2) at 1.9 microC/kg. Nevertheless, the DQE showed strong exposure and frequency dependencies. The results indicated that the detector offered high MTFs and DQEs, but structured noise effects may require improved calibration before clinical implementation.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

February 2005

Volume

32

Issue

2

Start / End Page

588 / 599

Location

United States

Related Subject Headings

  • X-Ray Intensifying Screens
  • Transducers
  • Signal Processing, Computer-Assisted
  • Selenium
  • Radiometry
  • Radiographic Image Enhancement
  • Radiation Dosage
  • Pilot Projects
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Saunders, R. S., Samei, E., Jesneck, J. L., & Lo, J. Y. (2005). Physical characterization of a prototype selenium-based full field digital mammography detector. Med Phys, 32(2), 588–599. https://doi.org/10.1118/1.1855033
Saunders, Robert S., Ehsan Samei, Jonathan L. Jesneck, and Joseph Y. Lo. “Physical characterization of a prototype selenium-based full field digital mammography detector.Med Phys 32, no. 2 (February 2005): 588–99. https://doi.org/10.1118/1.1855033.
Saunders RS, Samei E, Jesneck JL, Lo JY. Physical characterization of a prototype selenium-based full field digital mammography detector. Med Phys. 2005 Feb;32(2):588–99.
Saunders, Robert S., et al. “Physical characterization of a prototype selenium-based full field digital mammography detector.Med Phys, vol. 32, no. 2, Feb. 2005, pp. 588–99. Pubmed, doi:10.1118/1.1855033.
Saunders RS, Samei E, Jesneck JL, Lo JY. Physical characterization of a prototype selenium-based full field digital mammography detector. Med Phys. 2005 Feb;32(2):588–599.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

February 2005

Volume

32

Issue

2

Start / End Page

588 / 599

Location

United States

Related Subject Headings

  • X-Ray Intensifying Screens
  • Transducers
  • Signal Processing, Computer-Assisted
  • Selenium
  • Radiometry
  • Radiographic Image Enhancement
  • Radiation Dosage
  • Pilot Projects
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging