Skip to main content

System matrix modelling of externally tracked motion.

Publication ,  Journal Article
Rahmim, A; Cheng, J-C; Dinelle, K; Shilov, M; Segars, WP; Rousset, OG; Tsui, BMW; Wong, DF; Sossi, V
Published in: Nucl Med Commun
June 2008

BACKGROUND AND AIM: In high-resolution emission tomography imaging, even small patient movements can considerably degrade image quality. The aim of this work was to develop a general approach to motion-corrected reconstruction of motion-contaminated data in the case of rigid motion (particularly brain imaging) which would be applicable to any PET scanner in the field, without specialized data-acquisition requirements. METHODS: Assuming the ability to externally track subject motion during scanning (e.g., using the Polaris camera), we proposed to incorporate the measured rigid motion information into the system matrix of the expectation maximization reconstruction algorithm. Furthermore, we noted and developed a framework to incorporate the additional effect of motion on modifying the attenuation factors. A new mathematical brain phantom was developed and used along with elaborate combined Simset/GATE simulations to compare the proposed framework with the cases of no motion correction. RESULTS AND CONCLUSION: Clear qualitative and quantitative improvements were observed when incorporating the proposed framework. The method is very practical to implement for any scanner in the field, not requiring any hardware modifications or access to the list-mode acquisition capability.

Duke Scholars

Published In

Nucl Med Commun

DOI

ISSN

0143-3636

Publication Date

June 2008

Volume

29

Issue

6

Start / End Page

574 / 581

Location

England

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radionuclide Imaging
  • Pattern Recognition, Automated
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Models, Biological
  • Imaging, Three-Dimensional
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rahmim, A., Cheng, J.-C., Dinelle, K., Shilov, M., Segars, W. P., Rousset, O. G., … Sossi, V. (2008). System matrix modelling of externally tracked motion. Nucl Med Commun, 29(6), 574–581. https://doi.org/10.1097/MNM.0b013e3282f5d2de
Rahmim, Arman, Ju-Chieh Cheng, Katie Dinelle, Mikhail Shilov, W Paul Segars, Olivier G. Rousset, Benjamin M. W. Tsui, Dean F. Wong, and Vesna Sossi. “System matrix modelling of externally tracked motion.Nucl Med Commun 29, no. 6 (June 2008): 574–81. https://doi.org/10.1097/MNM.0b013e3282f5d2de.
Rahmim A, Cheng J-C, Dinelle K, Shilov M, Segars WP, Rousset OG, et al. System matrix modelling of externally tracked motion. Nucl Med Commun. 2008 Jun;29(6):574–81.
Rahmim, Arman, et al. “System matrix modelling of externally tracked motion.Nucl Med Commun, vol. 29, no. 6, June 2008, pp. 574–81. Pubmed, doi:10.1097/MNM.0b013e3282f5d2de.
Rahmim A, Cheng J-C, Dinelle K, Shilov M, Segars WP, Rousset OG, Tsui BMW, Wong DF, Sossi V. System matrix modelling of externally tracked motion. Nucl Med Commun. 2008 Jun;29(6):574–581.

Published In

Nucl Med Commun

DOI

ISSN

0143-3636

Publication Date

June 2008

Volume

29

Issue

6

Start / End Page

574 / 581

Location

England

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Radionuclide Imaging
  • Pattern Recognition, Automated
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Models, Biological
  • Imaging, Three-Dimensional
  • Image Interpretation, Computer-Assisted
  • Image Enhancement