Quality control phantom for digital chest radiography.

Publication ,  Journal Article
Chotas, HG; Floyd, CE; Johnson, GA; Ravin, CE
Published in: Radiology
January 1997

PURPOSE: To develop and test a chest phantom for routine quality control testing of digital radiography systems. MATERIALS AND METHODS: The phantom was constructed from sheets of copper, aluminum, and acrylic, which were cut and arranged to yield a radiographic projection resembling that of a human thorax. Regional test objects allowed quantitative assessment of optical density, contrast detail, and spatial resolution. Validation tests were performed to assess image stability in a stable imaging environment and sensitivity to changes in image quality when they occur. RESULTS: The phantom yielded consistent pseudoclinical images when used in a routine quality control program and facilitated detection of simulated problems that were induced in imaging system performance. CONCLUSION: The chest phantom enables quantitative, full-system testing of digital radiography system as they are used clinically for chest radiography.

Duke Scholars

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

January 1997

Volume

202

Issue

1

Start / End Page

111 / 116

Location

United States

Related Subject Headings

  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Humans
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chotas, H. G., Floyd, C. E., Johnson, G. A., & Ravin, C. E. (1997). Quality control phantom for digital chest radiography. Radiology, 202(1), 111–116. https://doi.org/10.1148/radiology.202.1.8988199
Chotas, H. G., C. E. Floyd, G. A. Johnson, and C. E. Ravin. “Quality control phantom for digital chest radiography.Radiology 202, no. 1 (January 1997): 111–16. https://doi.org/10.1148/radiology.202.1.8988199.
Chotas HG, Floyd CE, Johnson GA, Ravin CE. Quality control phantom for digital chest radiography. Radiology. 1997 Jan;202(1):111–6.
Chotas, H. G., et al. “Quality control phantom for digital chest radiography.Radiology, vol. 202, no. 1, Jan. 1997, pp. 111–16. Pubmed, doi:10.1148/radiology.202.1.8988199.
Chotas HG, Floyd CE, Johnson GA, Ravin CE. Quality control phantom for digital chest radiography. Radiology. 1997 Jan;202(1):111–116.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

January 1997

Volume

202

Issue

1

Start / End Page

111 / 116

Location

United States

Related Subject Headings

  • Radiography, Thoracic
  • Radiographic Image Enhancement
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Humans
  • 3202 Clinical sciences
  • 11 Medical and Health Sciences