Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios.
Publication
, Journal Article
Johnson, GA; Ravin, CE
Published in: Radiology
February 1981
This paper analyzes the contribution to scattered radiation at the film plane by individual components of a conventional wall-mounted cassette holder. With grid technique, scatter from the front panel of the cassette holder is effectively reduced, but considerable scatter reaches the film plane from the automatic exposure control pickup interposed between the grid and the film cassette. With air-gap technique (grid removed), the front panel of the cassette holder and the automatic exposure control pickup contribute equally to increased scattered radiation at the film plane. The contribution to the total scatter from the air-gap positioning plate is less significant.
Duke Scholars
Published In
Radiology
DOI
ISSN
0033-8419
Publication Date
February 1981
Volume
138
Issue
2
Start / End Page
461 / 464
Location
United States
Related Subject Headings
- Technology, Radiologic
- Scattering, Radiation
- Radiography
- Nuclear Medicine & Medical Imaging
- Humans
- 3202 Clinical sciences
- 11 Medical and Health Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Johnson, G. A., & Ravin, C. E. (1981). Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios. Radiology, 138(2), 461–464. https://doi.org/10.1148/radiology.138.2.7455131
Johnson, G. A., and C. E. Ravin. “Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios.” Radiology 138, no. 2 (February 1981): 461–64. https://doi.org/10.1148/radiology.138.2.7455131.
Johnson GA, Ravin CE. Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios. Radiology. 1981 Feb;138(2):461–4.
Johnson, G. A., and C. E. Ravin. “Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios.” Radiology, vol. 138, no. 2, Feb. 1981, pp. 461–64. Pubmed, doi:10.1148/radiology.138.2.7455131.
Johnson GA, Ravin CE. Effect of vertical cassette holder design and construction on scatter-to-primary radiation ratios. Radiology. 1981 Feb;138(2):461–464.
Published In
Radiology
DOI
ISSN
0033-8419
Publication Date
February 1981
Volume
138
Issue
2
Start / End Page
461 / 464
Location
United States
Related Subject Headings
- Technology, Radiologic
- Scattering, Radiation
- Radiography
- Nuclear Medicine & Medical Imaging
- Humans
- 3202 Clinical sciences
- 11 Medical and Health Sciences