Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique.

Publication ,  Journal Article
Stern, RL; Johnson, GA; Ravin, CE
Published in: Magn Reson Imaging
1990

A new pulse sequence designed for magnetic resonance imaging of the entire thoracic cavity is described. This sequence, called 3DPAUSE, is a rapid three-dimensional Fourier transform (3DFT) sequences with periodic pauses for breathing and additional rf pulses after each pause to restore the magnetization to steady-state before data acquisition resumes. Cardiac motion artifacts are effectively removed by signal averaging. Respiratory motion artifacts are removed by breath hold. Image artifacts caused by an inadequate number of pauses or by inappropriate placement of the pauses within a scan are shown, and ways to avoid these artifacts are discussed. 3DPAUSE provides the ability to acquire three-dimensional arrays in the thoracic cavity with minimal artifacts from respiratory and cardiac motions in a clinically reasonable time.

Duke Scholars

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1990

Volume

8

Issue

6

Start / End Page

747 / 753

Location

Netherlands

Related Subject Headings

  • Thorax
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Humans
  • Dogs
  • Animals
  • 3202 Clinical sciences
  • 1702 Cognitive Sciences
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stern, R. L., Johnson, G. A., & Ravin, C. E. (1990). Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique. Magn Reson Imaging, 8(6), 747–753. https://doi.org/10.1016/0730-725x(90)90010-y
Stern, R. L., G. A. Johnson, and C. E. Ravin. “Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique.Magn Reson Imaging 8, no. 6 (1990): 747–53. https://doi.org/10.1016/0730-725x(90)90010-y.
Stern RL, Johnson GA, Ravin CE. Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique. Magn Reson Imaging. 1990;8(6):747–53.
Stern, R. L., et al. “Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique.Magn Reson Imaging, vol. 8, no. 6, 1990, pp. 747–53. Pubmed, doi:10.1016/0730-725x(90)90010-y.
Stern RL, Johnson GA, Ravin CE. Magnetic resonance imaging of the thoracic cavity using a paused 3DFT acquisition technique. Magn Reson Imaging. 1990;8(6):747–753.
Journal cover image

Published In

Magn Reson Imaging

DOI

ISSN

0730-725X

Publication Date

1990

Volume

8

Issue

6

Start / End Page

747 / 753

Location

Netherlands

Related Subject Headings

  • Thorax
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Humans
  • Dogs
  • Animals
  • 3202 Clinical sciences
  • 1702 Cognitive Sciences
  • 1103 Clinical Sciences
  • 0903 Biomedical Engineering