PURPOSE: To determine the radiation dose to radiologists who perform computed tomographic (CT) fluoroscopic interventional procedures by using a quick-check method and a low-milliampere technique. MATERIALS AND METHODS: Two hundred twenty CT fluoroscopy--guided interventional procedures were performed in 189 patients. Procedures included 57 spinal injections, 17 spinal biopsies, 24 chest biopsies, 20 abdominal aspirations, 44 abdominal biopsies, and 58 abdominal drainages. Procedure details were prospectively recorded and included site, depth, target diameter, milliampere value, kilovolt peak, fluoroscopic time, and CT technique (continuous CT fluoroscopy, quick-check method, or a combination of these techniques). An individual collar and finger radiation detector were worn by each radiologist during each procedure to determine the dose per procedure. RESULTS: The quick-check technique was performed in 191 (87%) of 220 procedures. Four procedures were performed with continuous CT fluoroscopy, and a combination technique was used for 25 (11%) procedures. The overall mean CT fluoroscopic time was 17.9 seconds (range, 1.2--101.5 seconds). The mean milliampere value was 13.2 mA (range, 10--50 mA). The overall mean radiologist radiation dose per procedure was 2.5 mrem (0.025 mSv) (whole body). Individual procedure doses ranged from 0.66 to 4.75 mrem (0.007--0.048 mSv). The finger radiation dose was negligible. CONCLUSION: By using a low-milliampere technique and the quick-check method, CT fluoroscopic time and radiation exposure can be minimized.

Duke Scholars

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

July 2001

Volume

220

Issue

1

Start / End Page

161 / 167

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Time Factors
  • Sensitivity and Specificity
  • Risk Factors
  • Risk Assessment
  • Radiometry
  • Radiology, Interventional
  • Radiation Protection
  • Radiation Monitoring
  • Radiation Dosage
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Paulson, E. K., Sheafor, D. H., Enterline, D. S., McAdams, H. P., & Yoshizumi, T. T. (2001). CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists. Radiology, 220(1), 161–167. https://doi.org/10.1148/radiology.220.1.r01jl29161
Paulson, E. K., D. H. Sheafor, D. S. Enterline, H. P. McAdams, and T. T. Yoshizumi. “CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.Radiology 220, no. 1 (July 2001): 161–67. https://doi.org/10.1148/radiology.220.1.r01jl29161.
Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001 Jul;220(1):161–7.
Paulson, E. K., et al. “CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists.Radiology, vol. 220, no. 1, July 2001, pp. 161–67. Pubmed, doi:10.1148/radiology.220.1.r01jl29161.
Paulson EK, Sheafor DH, Enterline DS, McAdams HP, Yoshizumi TT. CT fluoroscopy--guided interventional procedures: techniques and radiation dose to radiologists. Radiology. 2001 Jul;220(1):161–167.
Journal cover image

Published In

Radiology

DOI

ISSN

0033-8419

Publication Date

July 2001

Volume

220

Issue

1

Start / End Page

161 / 167

Location

United States

Related Subject Headings

  • Tomography, X-Ray Computed
  • Time Factors
  • Sensitivity and Specificity
  • Risk Factors
  • Risk Assessment
  • Radiometry
  • Radiology, Interventional
  • Radiation Protection
  • Radiation Monitoring
  • Radiation Dosage