Skip to main content
Journal cover image

Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.

Publication ,  Journal Article
Truong, T-K; Chen, N-K; Song, AW
Published in: Magn Reson Med
October 2010

Spiral imaging is vulnerable to spatial and temporal variations of the amplitude of the static magnetic field (B(0)) caused by susceptibility effects, eddy currents, chemical shifts, subject motion, physiological noise, and system instabilities, resulting in image blurring. Here, a novel off-resonance correction method is proposed to address these issues. A k-space energy spectrum analysis algorithm is first applied to inherently and dynamically generate a B(0) map from the k-space data at each time point, without requiring any additional data acquisition, pulse sequence modification, or phase unwrapping. A simulated phase evolution rewinding algorithm and an automatic residual deblurring algorithm are then used to correct for the blurring caused by both spatial and temporal B(0) variations, resulting in a high spatial and temporal fidelity. This method is validated against conventional B(0) mapping and deblurring methods, and its advantages for dynamic MRI applications are demonstrated in functional MRI studies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

October 2010

Volume

64

Issue

4

Start / End Page

1121 / 1127

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Pattern Recognition, Automated
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
  • Brain
  • Artifacts
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Truong, T.-K., Chen, N.-K., & Song, A. W. (2010). Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging. Magn Reson Med, 64(4), 1121–1127. https://doi.org/10.1002/mrm.22485
Truong, Trong-Kha, Nan-Kuei Chen, and Allen W. Song. “Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.Magn Reson Med 64, no. 4 (October 2010): 1121–27. https://doi.org/10.1002/mrm.22485.
Truong, Trong-Kha, et al. “Application of k-space energy spectrum analysis for inherent and dynamic B0 mapping and deblurring in spiral imaging.Magn Reson Med, vol. 64, no. 4, Oct. 2010, pp. 1121–27. Pubmed, doi:10.1002/mrm.22485.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

October 2010

Volume

64

Issue

4

Start / End Page

1121 / 1127

Location

United States

Related Subject Headings

  • Sensitivity and Specificity
  • Reproducibility of Results
  • Pattern Recognition, Automated
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
  • Brain
  • Artifacts