Multishot spiral imaging is a promising alternative to echo-planar imaging for high-resolution diffusion-weighted imaging and diffusion tensor imaging. However, subject motion in the presence of diffusion-weighting gradients causes phase inconsistencies among different shots, resulting in signal loss and aliasing artifacts in the reconstructed images. Such artifacts can be reduced using a variable-density spiral trajectory or a navigator echo, however at the cost of a longer scan time. Here, a novel iterative phase correction method is proposed to inherently correct for the motion-induced phase errors without requiring any additional scan time. In this initial study, numerical simulations and in vivo experiments are performed to demonstrate that the proposed method can effectively and efficiently correct for spatially linear phase errors caused by rigid-body motion in multishot spiral diffusion-weighted imaging of the human brain.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

October 2012

Volume

68

Issue

4

Start / End Page

1255 / 1261

Location

United States

Related Subject Headings

  • Spin Labels
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
  • Diffusion Magnetic Resonance Imaging
  • Brain
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Truong, T.-K., Chen, N.-K., & Song, A. W. (2012). Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging. Magn Reson Med, 68(4), 1255–1261. https://doi.org/10.1002/mrm.24124
Truong, Trong-Kha, Nan-kuei Chen, and Allen W. Song. “Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging.Magn Reson Med 68, no. 4 (October 2012): 1255–61. https://doi.org/10.1002/mrm.24124.
Truong T-K, Chen N-K, Song AW. Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging. Magn Reson Med. 2012 Oct;68(4):1255–61.
Truong, Trong-Kha, et al. “Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging.Magn Reson Med, vol. 68, no. 4, Oct. 2012, pp. 1255–61. Pubmed, doi:10.1002/mrm.24124.
Truong T-K, Chen N-K, Song AW. Inherent correction of motion-induced phase errors in multishot spiral diffusion-weighted imaging. Magn Reson Med. 2012 Oct;68(4):1255–1261.
Journal cover image

Published In

Magn Reson Med

DOI

EISSN

1522-2594

Publication Date

October 2012

Volume

68

Issue

4

Start / End Page

1255 / 1261

Location

United States

Related Subject Headings

  • Spin Labels
  • Sensitivity and Specificity
  • Reproducibility of Results
  • Nuclear Medicine & Medical Imaging
  • Motion
  • Image Interpretation, Computer-Assisted
  • Image Enhancement
  • Humans
  • Diffusion Magnetic Resonance Imaging
  • Brain