Skip to main content
construction release_alert
Scholars@Duke will be undergoing maintenance April 11-15. Some features may be unavailable during this time.
cancel

Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA.

Publication ,  Journal Article
Chang, Z; Xiang, Q-S
Published in: Med Phys
August 2007

The fast imaging method named skipped phase encoding and edge deghosting (SPEED) has been demonstrated to reduce scan time considerably with typical magnetic resonance imaging data. In this work, SPEED is simplified with improved efficiency to accelerate the scan of sparse objects; we refer to this method as S-SPEED. S-SPEED partially samples k-space into two interleaved data sets, each with the same skip size of N but a different relative shift in phase encoding. The sampled data are then Fourier transformed into two ghosted images with N aliasing ghosts. Given the sparseness of signal distribution, the ghosted images are simply modeled with a single-layer structure, analogous to that used in maximum-intensity projection. With an algorithm based on a least-square-error solution, a deghosted image is solved, and a residual map is output for quality control. S-SPEED can be generalized to include more layers with additional acquisitions for refined results. Without differential filtering and full central k-space sampling, S-SPEED reduces scan time further and achieves more straightforward reconstruction, as compared with SPEED. In this work, S-SPEED is applied to accelerate magnetic resonance angiography (MRA) by taking advantage of the sparse nature of MRA data. With sparse phantom data and in vivo phase contrast MRA data, S-SPEED is demonstrated to achieve satisfactory results with an acceleration factor of 5.5 using a single coil.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

August 2007

Volume

34

Issue

8

Start / End Page

3173 / 3182

Location

United States

Related Subject Headings

  • Software
  • Signal Processing, Computer-Assisted
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Angiography
  • Image Interpretation, Computer-Assisted
  • Humans
  • Head
  • Fourier Analysis
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Chang, Z., & Xiang, Q.-S. (2007). Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA. Med Phys, 34(8), 3173–3182. https://doi.org/10.1118/1.2750966
Chang, Zheng, and Qing-San Xiang. “Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA.Med Phys 34, no. 8 (August 2007): 3173–82. https://doi.org/10.1118/1.2750966.
Chang, Zheng, and Qing-San Xiang. “Simplified skipped phase encoding and edge deghosting (SPEED) for imaging sparse objects with applications to MRA.Med Phys, vol. 34, no. 8, Aug. 2007, pp. 3173–82. Pubmed, doi:10.1118/1.2750966.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

August 2007

Volume

34

Issue

8

Start / End Page

3173 / 3182

Location

United States

Related Subject Headings

  • Software
  • Signal Processing, Computer-Assisted
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Angiography
  • Image Interpretation, Computer-Assisted
  • Humans
  • Head
  • Fourier Analysis