Skip to main content

Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols.

Publication ,  Journal Article
Kim, S; Yoo, S; Yin, F-F; Samei, E; Yoshizumi, T
Published in: Med Phys
July 2010

PURPOSE: To assess imaging dose of partial and full-angle kilovoltage CBCT scan protocols and to evaluate image quality for each protocol. METHODS: The authors obtained the CT dose index (CTDI) of the kilovoltage CBCT protocols in an on-board imager by ion chamber (IC) measurements and Monte Carlo (MC) simulations. A total of six new CBCT scan protocols were evaluated: Standard-dose head (100 kVp, 151 mA s, partial-angle), low-dose head (100 kVp, 75 mA s, partial-angle), high-quality head (100 kVp, 754 mA s, partial-angle), pelvis (125 kVp, 706 mA s, full-angle), pelvis spotlight (125 kVp, 752 mA s, partial-angle), and low-dose thorax (110 kVp, 271 mA s, full-angle). Using the point dose method, various CTDI values were calculated by (1) the conventional weighted CTDI (CTDIw) calculation and (2) Bakalyar's method (CTDIwb). The MC simulations were performed to obtain the CTDIw and CTDIwb, as well as from (3) central slice averaging (CTDI(2D)) and (4) volume averaging (CTDI(3D)) techniques. The CTDI values of the new protocols were compared to those of the old protocols (full-angle CBCT protocols). Image quality of the new protocols was evaluated following the CBCT image quality assurance (QA) protocol [S. Yoo et al., "A quality assurance program for the on-board image, "Med. Phys. 33(11), 4431-4447 (2006)] testing Hounsfield unit (HU) linearity, spatial linearity/resolution, contrast resolution, and HU uniformity. RESULTS: The CTDI, were found as 6.0, 3.2, 29.0, 25.4, 23.8, and 7.7 mGy for the new protocols, respectively. The CTDI, and CTDIwb differed within +3% between IC measurements and MC simulations. Method (2) results were within +/- 12% of method (1). In MC simulations, the CTDIw and CTDIwb were comparable to the CTDI(2D) and CTDI(3D) with the differences ranging from -4.3% to 20.6%. The CTDI(3D) were smallest among all the CTDI values. CTDIw of the new protocols were found as approximately 14 times lower for standard head scan and 1.8 times lower for standard body scan than the old protocols, respectively. In the image quality QA tests, all the protocols except low-dose head and low-dose thorax protocols were within the tolerance in the HU verification test. The HU value for the two protocols was always higher than the nominal value. All the protocols passed the spatial linearity/resolution and HU uniformity tests. In the contrast resolution test, only high-quality head and pelvis scan protocols were within the tolerance. In addition, crescent effect was found in the partial-angle scan protocols. CONCLUSIONS: The authors found that CTDIw of the new CBCT protocols has been significantly reduced compared to the old protocols with acceptable image quality. The CTDIw values in the point dose method were close to the volume averaging method within 9%-21% for all the CBCT scan protocols. The Bakalyar's method produced more accurate dose estimation within 14%. The HU inaccuracy from low-dose head and low-dose thorax protocols can render incorrect dose results in the treatment planning system. When high soft-tissue contrast data are desired, high-quality head or pelvis scan protocol is recommended depending on the imaging area. The point dose method can be applicable to estimate CBCT dose with reasonable accuracy in the clinical environment.

Duke Scholars

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

July 2010

Volume

37

Issue

7

Start / End Page

3648 / 3659

Location

United States

Related Subject Headings

  • Radiation Dosage
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Linear Models
  • Cone-Beam Computed Tomography
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Kim, S., Yoo, S., Yin, F.-F., Samei, E., & Yoshizumi, T. (2010). Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols. Med Phys, 37(7), 3648–3659. https://doi.org/10.1118/1.3438478
Kim, Sangroh, Sua Yoo, Fang-Fang Yin, Ehsan Samei, and Terry Yoshizumi. “Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols.Med Phys 37, no. 7 (July 2010): 3648–59. https://doi.org/10.1118/1.3438478.
Kim S, Yoo S, Yin F-F, Samei E, Yoshizumi T. Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols. Med Phys. 2010 Jul;37(7):3648–59.
Kim, Sangroh, et al. “Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols.Med Phys, vol. 37, no. 7, July 2010, pp. 3648–59. Pubmed, doi:10.1118/1.3438478.
Kim S, Yoo S, Yin F-F, Samei E, Yoshizumi T. Kilovoltage cone-beam CT: comparative dose and image quality evaluations in partial and full-angle scan protocols. Med Phys. 2010 Jul;37(7):3648–3659.

Published In

Med Phys

DOI

ISSN

0094-2405

Publication Date

July 2010

Volume

37

Issue

7

Start / End Page

3648 / 3659

Location

United States

Related Subject Headings

  • Radiation Dosage
  • Quality Control
  • Phantoms, Imaging
  • Nuclear Medicine & Medical Imaging
  • Linear Models
  • Cone-Beam Computed Tomography
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering