Skip to main content

Evaluation of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils.

Publication ,  Journal Article
Ralston, MD; Pizzo, S; Woodfield, S; Thompson, WM
Published in: Invest Radiol
1983

A technique was developed to evaluate the degree of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils. The kidneys of mongrel dogs were used to collect emboli distal to conventional TCEC or Gianturco coil occlusion of the renal arteries. TCEC controls (TCEC setup without current), normal kidneys, kidneys embolized with autologous clot, and kidneys whose renal arteries were surgically ligated were evaluated for comparison. The renal vasculature was flushed and then fixed by glutaraldehyde infusion. The kidneys were filled with a barium gelatin mixture and examined both radiographically and pathologically. The four normal kidneys and the four ligated kidneys gave a characteristic complete filling of the vascular web, while filling defects were evident in the following conditions: 3/12 TCEC controls; 26/34 with TCEC occlusion; 6/10 with Gianturco coils; and 11/11 with autologous clot. An excellent correlation existed between radiographic intraluminal filling defects and grossly and microscopically identified emboli.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Invest Radiol

DOI

ISSN

0020-9996

Publication Date

1983

Volume

18

Issue

2

Start / End Page

171 / 176

Location

United States

Related Subject Headings

  • Renal Circulation
  • Renal Artery
  • Radiography
  • Nuclear Medicine & Medical Imaging
  • Models, Biological
  • Kidney
  • Embolization, Therapeutic
  • Embolism
  • Electrocoagulation
  • Dogs
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Ralston, M. D., Pizzo, S., Woodfield, S., & Thompson, W. M. (1983). Evaluation of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils. Invest Radiol, 18(2), 171–176. https://doi.org/10.1097/00004424-198303000-00014
Ralston, M. D., S. Pizzo, S. Woodfield, and W. M. Thompson. “Evaluation of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils.Invest Radiol 18, no. 2 (1983): 171–76. https://doi.org/10.1097/00004424-198303000-00014.
Ralston MD, Pizzo S, Woodfield S, Thompson WM. Evaluation of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils. Invest Radiol. 1983;18(2):171–6.
Ralston, M. D., et al. “Evaluation of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils.Invest Radiol, vol. 18, no. 2, 1983, pp. 171–76. Pubmed, doi:10.1097/00004424-198303000-00014.
Ralston MD, Pizzo S, Woodfield S, Thompson WM. Evaluation of embolization distal to arterial occlusion by transcatheter electrocoagulation (TCEC) and Gianturco coils. Invest Radiol. 1983;18(2):171–176.

Published In

Invest Radiol

DOI

ISSN

0020-9996

Publication Date

1983

Volume

18

Issue

2

Start / End Page

171 / 176

Location

United States

Related Subject Headings

  • Renal Circulation
  • Renal Artery
  • Radiography
  • Nuclear Medicine & Medical Imaging
  • Models, Biological
  • Kidney
  • Embolization, Therapeutic
  • Embolism
  • Electrocoagulation
  • Dogs