Skip to main content

Fundamental Correlation Lengths of Coherent Speckle in Medical Ultrasonic Images

Publication ,  Journal Article
Wagnef, RF; Ins An A, MF; Smith, SW
Published in: IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
January 1, 1988

Refinements to previous analyses of the natural correlation lengths within simple images and between images to be compounded are presented. Comparison of theoretical and experimental results show very good agreement for the case of Rayleigh scattering media: the correlation length within a simple image is comparable to the resolution cell size; the correlation length between images to be spatially compounded is comparable to, but smaller than, the transducer or array aperture; and the correlation length between images to be frequency compounded becomes a frequency comparable to their bandwidth. Complications arising from the presence of specular scattering or due to the presence of just a few scatterers are considered. It is shown that straightforward solutions exist for either one of these problems taken by itself. When they occur in combination, calibration techniques may lead to unambiguous identification of the contributions to the scattering from diffuse or incoherent scattering and from specular or coherent scattering, and to estimation of the density of diffuse scatterers. © 1988 IEEE

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

DOI

ISSN

0885-3010

Publication Date

January 1, 1988

Volume

35

Issue

1

Start / End Page

34 / 44

Related Subject Headings

  • Acoustics
  • 51 Physical sciences
  • 40 Engineering
  • 09 Engineering
  • 02 Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wagnef, R. F., Ins An A, M. F., & Smith, S. W. (1988). Fundamental Correlation Lengths of Coherent Speckle in Medical Ultrasonic Images. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 35(1), 34–44. https://doi.org/10.1109/58.4145
Wagnef, R. F., M. F. Ins An A, and S. W. Smith. “Fundamental Correlation Lengths of Coherent Speckle in Medical Ultrasonic Images.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 35, no. 1 (January 1, 1988): 34–44. https://doi.org/10.1109/58.4145.
Wagnef RF, Ins An A MF, Smith SW. Fundamental Correlation Lengths of Coherent Speckle in Medical Ultrasonic Images. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 1988 Jan 1;35(1):34–44.
Wagnef, R. F., et al. “Fundamental Correlation Lengths of Coherent Speckle in Medical Ultrasonic Images.” IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 35, no. 1, Jan. 1988, pp. 34–44. Scopus, doi:10.1109/58.4145.
Wagnef RF, Ins An A MF, Smith SW. Fundamental Correlation Lengths of Coherent Speckle in Medical Ultrasonic Images. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control. 1988 Jan 1;35(1):34–44.

Published In

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control

DOI

ISSN

0885-3010

Publication Date

January 1, 1988

Volume

35

Issue

1

Start / End Page

34 / 44

Related Subject Headings

  • Acoustics
  • 51 Physical sciences
  • 40 Engineering
  • 09 Engineering
  • 02 Physical Sciences