Angular response of miniature ultrasonic hydrophones.

Publication ,  Journal Article
Shombert, DG; Smith, SW; Harris, GR
Published in: Medical physics
July 1982

The voltage response of ceramic and polyvinylidene fluoride (PVDF) hydrophones was measured in the receive mode for angles of incidence ranging from 0 degrees to 90 degrees. The measurements were performed at 2.5, 3.5, 5.0, and 8.0 MHz; these frequencies are typical of those used in medical diagnosis. The results are compared to three theoretical models based on diffraction theory; correlation between the measured response and theoretical models is evident for some PVDF hydrophones but not for others, and not for any ceramic hydrophone. The effective radius, as defined in the AIUM-NEMA standard for diagnosis ultrasound, is calculated and compared to the test criteria established in that standard. All of the ceramic hydrophones and two of the five PVDF hydrophones failed to meet the criteria.

Duke Scholars

Published In

Medical physics

DOI

EISSN

2473-4209

ISSN

0094-2405

Publication Date

July 1982

Volume

9

Issue

4

Start / End Page

484 / 492

Related Subject Headings

  • Ultrasonography
  • Ultrasonics
  • Polyvinyls
  • Nuclear Medicine & Medical Imaging
  • Ceramics
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Shombert, D. G., Smith, S. W., & Harris, G. R. (1982). Angular response of miniature ultrasonic hydrophones. Medical Physics, 9(4), 484–492. https://doi.org/10.1118/1.595114
Shombert, D. G., S. W. Smith, and G. R. Harris. “Angular response of miniature ultrasonic hydrophones.Medical Physics 9, no. 4 (July 1982): 484–92. https://doi.org/10.1118/1.595114.
Shombert DG, Smith SW, Harris GR. Angular response of miniature ultrasonic hydrophones. Medical physics. 1982 Jul;9(4):484–92.
Shombert, D. G., et al. “Angular response of miniature ultrasonic hydrophones.Medical Physics, vol. 9, no. 4, July 1982, pp. 484–92. Epmc, doi:10.1118/1.595114.
Shombert DG, Smith SW, Harris GR. Angular response of miniature ultrasonic hydrophones. Medical physics. 1982 Jul;9(4):484–492.

Published In

Medical physics

DOI

EISSN

2473-4209

ISSN

0094-2405

Publication Date

July 1982

Volume

9

Issue

4

Start / End Page

484 / 492

Related Subject Headings

  • Ultrasonography
  • Ultrasonics
  • Polyvinyls
  • Nuclear Medicine & Medical Imaging
  • Ceramics
  • 5105 Medical and biological physics
  • 4003 Biomedical engineering
  • 1112 Oncology and Carcinogenesis
  • 0903 Biomedical Engineering
  • 0299 Other Physical Sciences