Improving earpiece accelerometer coupling to the head

Publication ,  Journal Article
Salzar, RS; Bass, CRD; Pellettiere, JA
Published in: SAE Technical Papers
January 1, 2008

As accurate measuring of head accelerations is an important aspect in predicting head injury, it is important that the measuring sensor be well-coupled to the head. Various sensors and sensor mounting schemes have been attempted in the past with varying results. This study uses a small, implantable acceleration sensor pack in the ear to study impact coupling with the human skull. The output from these ear-mounted accelerometers is compared to laboratory reference accelerometers rigidly attached to the skull of two cadaveric head specimens for both low-amplitude oscillatory tests and high-amplitude impact drop tests. The combination of sensor type and mounting scheme demonstrates the feasibility of using ear mounted sensors to predict head acceleration response. Previously reported progressive phase lag was not seen in this study, with the comparison between ear mounted accelerometers and rigidly mounted head accelerometers ranging from very good to excellent.

Duke Scholars

Published In

SAE Technical Papers

DOI

EISSN

2688-3627

ISSN

0148-7191

Publication Date

January 1, 2008

Related Subject Headings

  • 4014 Manufacturing engineering
  • 4002 Automotive engineering
  • 0910 Manufacturing Engineering
  • 0902 Automotive Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Salzar, R. S., Bass, C. R. D., & Pellettiere, J. A. (2008). Improving earpiece accelerometer coupling to the head. SAE Technical Papers. https://doi.org/10.4271/2008-01-2978
Salzar, R. S., C. R. D. Bass, and J. A. Pellettiere. “Improving earpiece accelerometer coupling to the head.” SAE Technical Papers, January 1, 2008. https://doi.org/10.4271/2008-01-2978.
Salzar RS, Bass CRD, Pellettiere JA. Improving earpiece accelerometer coupling to the head. SAE Technical Papers. 2008 Jan 1;
Salzar, R. S., et al. “Improving earpiece accelerometer coupling to the head.” SAE Technical Papers, Jan. 2008. Scopus, doi:10.4271/2008-01-2978.
Salzar RS, Bass CRD, Pellettiere JA. Improving earpiece accelerometer coupling to the head. SAE Technical Papers. 2008 Jan 1;