Skip to main content

Patient specific computerized phantoms to estimate dose in pediatric CT

Publication ,  Journal Article
Segars, WP; Sturgeon, G; Li, X; Cheng, L; Ceritoglu, C; Ratnanather, JT; Miller, MI; Tsui, BMW; Frush, D; Samei, E
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
June 16, 2009

We create a series of detailed computerized phantoms to estimate patient organ and effective dose in pediatric CT and investigate techniques for efficiently creating patient-specific phantoms based on imaging data. The initial anatomy of each phantom was previously developed based on manual segmentation of pediatric CT data. Each phantom was extended to include a more detailed anatomy based on morphing an existing adult phantom in our laboratory to match the framework (based on segmentation) defined for the target pediatric model. By morphing a template anatomy to match the patient data in the LDDMM framework, it was possible to create a patient specific phantom with many anatomical structures, some not visible in the CT data. The adult models contain thousands of defined structures that were transformed to define them in each pediatric anatomy. The accuracy of this method, under different conditions, was tested using a known voxelized phantom as the target. Errors were measured in terms of a distance map between the predicted organ surfaces and the known ones. We also compared calculated dose measurements to see the effect of different magnitudes of errors in morphing. Despite some variations in organ geometry, dose measurements from morphing predictions were found to agree with those calculated from the voxelized phantom thus demonstrating the feasibility of our methods. © 2009 SPIE.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 16, 2009

Volume

7258
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Segars, W. P., Sturgeon, G., Li, X., Cheng, L., Ceritoglu, C., Ratnanather, J. T., … Samei, E. (2009). Patient specific computerized phantoms to estimate dose in pediatric CT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 7258. https://doi.org/10.1117/12.813517
Segars, W. P., G. Sturgeon, X. Li, L. Cheng, C. Ceritoglu, J. T. Ratnanather, M. I. Miller, B. M. W. Tsui, D. Frush, and E. Samei. “Patient specific computerized phantoms to estimate dose in pediatric CT.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 7258 (June 16, 2009). https://doi.org/10.1117/12.813517.
Segars WP, Sturgeon G, Li X, Cheng L, Ceritoglu C, Ratnanather JT, et al. Patient specific computerized phantoms to estimate dose in pediatric CT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2009 Jun 16;7258.
Segars, W. P., et al. “Patient specific computerized phantoms to estimate dose in pediatric CT.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 7258, June 2009. Scopus, doi:10.1117/12.813517.
Segars WP, Sturgeon G, Li X, Cheng L, Ceritoglu C, Ratnanather JT, Miller MI, Tsui BMW, Frush D, Samei E. Patient specific computerized phantoms to estimate dose in pediatric CT. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2009 Jun 16;7258.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 16, 2009

Volume

7258