Skip to main content

Continual in vivo assessment of 1 mm diameter vascular prostheses

Publication ,  Other
Skarada, DJ; du Laney, TV; Steele, TM; Ritter, EF; Klitzman, B
Published in: Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the International Biomaterials Symposium
December 1, 1996

An in vivo model of small diameter vascular grafts is developed to quantitatively described the effects of graft treatments on downstream tissue. The model shows that heparin treated grafts and endothelialized grafts performed better than the untreated ePTFE used in distal limb revascularization. Furthermore, the heparinized grafts significantly improves the oxygenation and blood flow in downstream tissue.

Duke Scholars

Published In

Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the International Biomaterials Symposium

Publication Date

December 1, 1996

Volume

1

Start / End Page

278
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Skarada, D. J., du Laney, T. V., Steele, T. M., Ritter, E. F., & Klitzman, B. (1996). Continual in vivo assessment of 1 mm diameter vascular prostheses. Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the International Biomaterials Symposium.
Skarada, D. J., T. V. du Laney, T. M. Steele, E. F. Ritter, and B. Klitzman. “Continual in vivo assessment of 1 mm diameter vascular prostheses.” Transactions of the Annual Meeting of the Society for Biomaterials in Conjunction with the International Biomaterials Symposium, December 1, 1996.
Skarada DJ, du Laney TV, Steele TM, Ritter EF, Klitzman B. Continual in vivo assessment of 1 mm diameter vascular prostheses. Vol. 1, Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the International Biomaterials Symposium. 1996. p. 278.
Skarada, D. J., et al. “Continual in vivo assessment of 1 mm diameter vascular prostheses.” Transactions of the Annual Meeting of the Society for Biomaterials in Conjunction with the International Biomaterials Symposium, vol. 1, 1 Dec. 1996, p. 278.
Skarada DJ, du Laney TV, Steele TM, Ritter EF, Klitzman B. Continual in vivo assessment of 1 mm diameter vascular prostheses. Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the International Biomaterials Symposium. 1996. p. 278.

Published In

Transactions of the Annual Meeting of the Society for Biomaterials in conjunction with the International Biomaterials Symposium

Publication Date

December 1, 1996

Volume

1

Start / End Page

278