Skip to main content

Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images.

Publication ,  Journal Article
Rouze, NC; Wang, MH; Palmeri, ML; Nightingale, KR
Published in: IEEE transactions on ultrasonics, ferroelectrics, and frequency control
August 2012

Time-of-flight methods allow quantitative measurement of shear wave speed (SWS) from ultrasonically tracked displacements following impulsive acoustic radiation force excitation in tissue. In heterogeneous materials, reflections at boundaries can distort the wave shape and confound determination of the wave arrival time. The magnitude of these effects depends on the shear wavelength of the excitation, the kernel size used to calculate the SWS, and the method used to determine the wave arrival time. In this study, we perform a parametric analysis of these factors using finite element modeling of the tissue response and simulated ultrasonic tracking. Two geometries are used, a stiff vertical layer and a stiff spherical inclusion, each in a uniform background. Wave arrival times are estimated using the peak displacement, peak slope of the leading edge, and cross-correlation methods. Results are evaluated in terms of reconstruction accuracy, resolution, contrast, and contrast-to-noise ratio of reconstructed SWS images. Superior results are obtained using narrower excitation widths and arrival time estimators which identify the leading edge of the propagating wave. The optimal kernel size is determined by a tradeoff between improved accuracy for larger kernels at the expense of spatial resolution.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

IEEE transactions on ultrasonics, ferroelectrics, and frequency control

DOI

EISSN

1525-8955

ISSN

0885-3010

Publication Date

August 2012

Volume

59

Issue

8

Start / End Page

1729 / 1740

Related Subject Headings

  • Poisson Distribution
  • Image Processing, Computer-Assisted
  • Finite Element Analysis
  • Elasticity Imaging Techniques
  • Elastic Modulus
  • Computer Simulation
  • Algorithms
  • Acoustics
  • 51 Physical sciences
  • 40 Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rouze, N. C., Wang, M. H., Palmeri, M. L., & Nightingale, K. R. (2012). Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images. IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, 59(8), 1729–1740. https://doi.org/10.1109/tuffc.2012.2377
Rouze, Ned C., Michael H. Wang, Mark L. Palmeri, and Kathryn R. Nightingale. “Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images.IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control 59, no. 8 (August 2012): 1729–40. https://doi.org/10.1109/tuffc.2012.2377.
Rouze NC, Wang MH, Palmeri ML, Nightingale KR. Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images. IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 2012 Aug;59(8):1729–40.
Rouze, Ned C., et al. “Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images.IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control, vol. 59, no. 8, Aug. 2012, pp. 1729–40. Epmc, doi:10.1109/tuffc.2012.2377.
Rouze NC, Wang MH, Palmeri ML, Nightingale KR. Parameters affecting the resolution and accuracy of 2-D quantitative shear wave images. IEEE transactions on ultrasonics, ferroelectrics, and frequency control. 2012 Aug;59(8):1729–1740.

Published In

IEEE transactions on ultrasonics, ferroelectrics, and frequency control

DOI

EISSN

1525-8955

ISSN

0885-3010

Publication Date

August 2012

Volume

59

Issue

8

Start / End Page

1729 / 1740

Related Subject Headings

  • Poisson Distribution
  • Image Processing, Computer-Assisted
  • Finite Element Analysis
  • Elasticity Imaging Techniques
  • Elastic Modulus
  • Computer Simulation
  • Algorithms
  • Acoustics
  • 51 Physical sciences
  • 40 Engineering