The Maltese cross processor: speckle reduction for circular transducers.

Publication ,  Journal Article
Smith, SW; von Ramm, OT
Published in: Ultrasonic imaging
July 1988

A new online signal processing technique is described to reduce speckle noise in ultrasound images. In the imaging system, a focused piston transducer is divided into thirty-two sectors. In the receive mode, parallel signal processing arranges the sectors into eight maltese crosses. The rf signals of the perpendicular arms of each cross are multiplied in a phase sensitive process. The orthogonal receive mode multiplication is designed to reduce side lobes resulting from the sector shapes while maintaining lateral resolution through the use of the full aperture diameter. The signals from the crosses are then combined via postdetection summation. Six of the eight crosses perform successfully. The six maltese crosses show decorrelated signals equivalent to four independent samples of the speckle noise which decreases noise contrast by a factor of two with no measureable loss of spatial resolution. Post summation compression is included to retain the conventional signal dynamic range. Parallel signal processing maintains the normal image line rate. Images of tissue-mimicking phantoms including speckle targets show improved detectability of simulated lesions.

Duke Scholars

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

July 1988

Volume

10

Issue

3

Start / End Page

153 / 170

Related Subject Headings

  • Ultrasonography
  • Transducers
  • Models, Structural
  • Image Enhancement
  • Humans
  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Smith, S. W., & von Ramm, O. T. (1988). The Maltese cross processor: speckle reduction for circular transducers. Ultrasonic Imaging, 10(3), 153–170. https://doi.org/10.1177/016173468801000301
Smith, S. W., and O. T. von Ramm. “The Maltese cross processor: speckle reduction for circular transducers.Ultrasonic Imaging 10, no. 3 (July 1988): 153–70. https://doi.org/10.1177/016173468801000301.
Smith SW, von Ramm OT. The Maltese cross processor: speckle reduction for circular transducers. Ultrasonic imaging. 1988 Jul;10(3):153–70.
Smith, S. W., and O. T. von Ramm. “The Maltese cross processor: speckle reduction for circular transducers.Ultrasonic Imaging, vol. 10, no. 3, July 1988, pp. 153–70. Epmc, doi:10.1177/016173468801000301.
Smith SW, von Ramm OT. The Maltese cross processor: speckle reduction for circular transducers. Ultrasonic imaging. 1988 Jul;10(3):153–170.
Journal cover image

Published In

Ultrasonic imaging

DOI

EISSN

1096-0910

ISSN

0161-7346

Publication Date

July 1988

Volume

10

Issue

3

Start / End Page

153 / 170

Related Subject Headings

  • Ultrasonography
  • Transducers
  • Models, Structural
  • Image Enhancement
  • Humans
  • Acoustics
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering