Skip to main content

Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes.

Publication ,  Journal Article
Tang, AS; Wolf, PD; Afework, Y; Smith, WM; Ideker, RE
Published in: Circulation
May 1992

Defibrillation may be improved if electrode configurations can be found that create a larger and more even voltage gradient field across the heart. This study determined the magnitude of the shock gradient fields generated by four nonthoracotomy electrode configurations for defibrillation.In six dogs, a catheter was inserted containing a right ventricular apical electrode (V) and a right atrial electrode (A). A cutaneous patch electrode (P) was placed on the left lateral thorax. Shock potentials were recorded simultaneously from 128 electrodes in the left ventricular and right ventricular subepicardium and subendocardium, ventricular septum, and atria. With the chest closed, 50-mA shocks were given during diastole via the following lead configurations: V----A (V, cathode; A, anode); V----P; V----A+P; and V+A----P. Potential gradients were calculated at the subepicardium and subendocardium in millivolts per centimeter per volt of shock. In most dogs, the V----A+P configuration produced higher gradients throughout the ventricles than did V----A, V----P, or V+A----P. The maximum potential gradient was smaller for the V+A----P configuration than for V----A, V----P, or V----A+P. The gradient fields for the configurations with the catheter alone or combined with P were uneven.It is possible to estimate shock gradient fields in three dimensions. Of the four configurations tested, V----A+P produced the highest gradients and V+A----P produced the lowest high gradient. The gradient fields were uneven throughout the ventricles.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circulation

DOI

EISSN

1524-4539

ISSN

0009-7322

Publication Date

May 1992

Volume

85

Issue

5

Start / End Page

1857 / 1864

Related Subject Headings

  • Skin
  • Heart
  • Electrophysiology
  • Electrodes
  • Electric Countershock
  • Dogs
  • Cardiovascular System & Hematology
  • Cardiac Catheterization
  • Animals
  • 1117 Public Health and Health Services
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tang, A. S., Wolf, P. D., Afework, Y., Smith, W. M., & Ideker, R. E. (1992). Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes. Circulation, 85(5), 1857–1864. https://doi.org/10.1161/01.cir.85.5.1857
Tang, A. S., P. D. Wolf, Y. Afework, W. M. Smith, and R. E. Ideker. “Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes.Circulation 85, no. 5 (May 1992): 1857–64. https://doi.org/10.1161/01.cir.85.5.1857.
Tang AS, Wolf PD, Afework Y, Smith WM, Ideker RE. Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes. Circulation. 1992 May;85(5):1857–64.
Tang, A. S., et al. “Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes.Circulation, vol. 85, no. 5, May 1992, pp. 1857–64. Epmc, doi:10.1161/01.cir.85.5.1857.
Tang AS, Wolf PD, Afework Y, Smith WM, Ideker RE. Three-dimensional potential gradient fields generated by intracardiac catheter and cutaneous patch electrodes. Circulation. 1992 May;85(5):1857–1864.

Published In

Circulation

DOI

EISSN

1524-4539

ISSN

0009-7322

Publication Date

May 1992

Volume

85

Issue

5

Start / End Page

1857 / 1864

Related Subject Headings

  • Skin
  • Heart
  • Electrophysiology
  • Electrodes
  • Electric Countershock
  • Dogs
  • Cardiovascular System & Hematology
  • Cardiac Catheterization
  • Animals
  • 1117 Public Health and Health Services