DAMAGE TO POLYMER SURFACE AND DETACHMENT OF POLYMER FRAGMENTS DURING DELIVERY BALLOON EXPANSION OF DRUG-ELUTING STENTS: A PREVIOUSLY UNRECOGNIZED SOURCE FOR ADVERSE OUTCOMES
Publication
, Conference
Denardo, SJ; Carpinone, PL; Vock, DM; Tcheng, JE; Phillips, III, HR; Batich, CD; Pepine, CJ
Published in: Journal of the American College of Cardiology
March 2012
Duke Scholars
Published In
Journal of the American College of Cardiology
DOI
ISSN
0735-1097
Publication Date
March 2012
Volume
59
Issue
13
Start / End Page
E218 / E218
Publisher
Elsevier BV
Related Subject Headings
- Cardiovascular System & Hematology
- 3201 Cardiovascular medicine and haematology
- 1117 Public Health and Health Services
- 1102 Cardiorespiratory Medicine and Haematology
Citation
APA
Chicago
ICMJE
MLA
NLM
Denardo, S. J., Carpinone, P. L., Vock, D. M., Tcheng, J. E., Phillips, III, H. R., Batich, C. D., & Pepine, C. J. (2012). DAMAGE TO POLYMER SURFACE AND DETACHMENT OF POLYMER FRAGMENTS DURING DELIVERY BALLOON EXPANSION OF DRUG-ELUTING STENTS: A PREVIOUSLY UNRECOGNIZED SOURCE FOR ADVERSE OUTCOMES. In Journal of the American College of Cardiology (Vol. 59, pp. E218–E218). Elsevier BV. https://doi.org/10.1016/s0735-1097(12)60219-8
Denardo, Scott J., Paul L. Carpinone, David M. Vock, James E. Tcheng, Harry R. Phillips, III, Christopher D. Batich, and Carl J. Pepine. “DAMAGE TO POLYMER SURFACE AND DETACHMENT OF POLYMER FRAGMENTS DURING DELIVERY BALLOON EXPANSION OF DRUG-ELUTING STENTS: A PREVIOUSLY UNRECOGNIZED SOURCE FOR ADVERSE OUTCOMES.” In Journal of the American College of Cardiology, 59:E218–E218. Elsevier BV, 2012. https://doi.org/10.1016/s0735-1097(12)60219-8.
Denardo SJ, Carpinone PL, Vock DM, Tcheng JE, Phillips, III HR, Batich CD, et al. DAMAGE TO POLYMER SURFACE AND DETACHMENT OF POLYMER FRAGMENTS DURING DELIVERY BALLOON EXPANSION OF DRUG-ELUTING STENTS: A PREVIOUSLY UNRECOGNIZED SOURCE FOR ADVERSE OUTCOMES. In: Journal of the American College of Cardiology. Elsevier BV; 2012. p. E218–E218.
Denardo, Scott J., et al. “DAMAGE TO POLYMER SURFACE AND DETACHMENT OF POLYMER FRAGMENTS DURING DELIVERY BALLOON EXPANSION OF DRUG-ELUTING STENTS: A PREVIOUSLY UNRECOGNIZED SOURCE FOR ADVERSE OUTCOMES.” Journal of the American College of Cardiology, vol. 59, no. 13, Elsevier BV, 2012, pp. E218–E218. Crossref, doi:10.1016/s0735-1097(12)60219-8.
Denardo SJ, Carpinone PL, Vock DM, Tcheng JE, Phillips, III HR, Batich CD, Pepine CJ. DAMAGE TO POLYMER SURFACE AND DETACHMENT OF POLYMER FRAGMENTS DURING DELIVERY BALLOON EXPANSION OF DRUG-ELUTING STENTS: A PREVIOUSLY UNRECOGNIZED SOURCE FOR ADVERSE OUTCOMES. Journal of the American College of Cardiology. Elsevier BV; 2012. p. E218–E218.
Published In
Journal of the American College of Cardiology
DOI
ISSN
0735-1097
Publication Date
March 2012
Volume
59
Issue
13
Start / End Page
E218 / E218
Publisher
Elsevier BV
Related Subject Headings
- Cardiovascular System & Hematology
- 3201 Cardiovascular medicine and haematology
- 1117 Public Health and Health Services
- 1102 Cardiorespiratory Medicine and Haematology