Skip to main content

Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients

Publication ,  Journal Article
Zhang, Y; Li, X; Paul Segars, W; Samei, E
Published in: Progress in Biomedical Optics and Imaging - Proceedings of SPIE
June 3, 2013

There are three main x-ray based modalities for imaging the thorax: radiography, tomosynthesis, and CT. CT provides perhaps the highest level of feature resolution but at notably higher radiation dose. To implement the ALARA (as low as reasonable achievable) principle in making an appropriate choice between standard chest projection imaging, tomosynthesis, and CT to achieve the lowest possible dose to patients, the effective doses and risk indices for each modality should be accurately known. In this study, we employed 59 computational anthropomorphic male and female extended cardiac-torso (XCAT) adult phantoms and a Monte Carlo simulation program (PENELOPE, version 2006, Universitat de Barcelona, Spain). Effective dose and risk index was estimated for a clinical radiography system enabling to conduct chest radiography and tomosynthesis sweep (Definium 8000, Volume RAD, GE Healthcare) and a clinical CT system (LightSpeed VCT, GE Healthcare). It was found that the absolute effective dose and risk index increased greatly with increasing patient size for CT, while these two dose metrics only increased slightly for radiography and tomosynthesis. This suggests that it is important to specify patient size when comparing radiation dose across imaging modalities. © 2013 SPIE.

Duke Scholars

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 3, 2013

Volume

8668
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, Y., Li, X., Paul Segars, W., & Samei, E. (2013). Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients. Progress in Biomedical Optics and Imaging - Proceedings of SPIE, 8668. https://doi.org/10.1117/12.2008544
Zhang, Y., X. Li, W. Paul Segars, and E. Samei. “Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE 8668 (June 3, 2013). https://doi.org/10.1117/12.2008544.
Zhang Y, Li X, Paul Segars W, Samei E. Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013 Jun 3;8668.
Zhang, Y., et al. “Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients.” Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 8668, June 2013. Scopus, doi:10.1117/12.2008544.
Zhang Y, Li X, Paul Segars W, Samei E. Comparative dosimetry of radiography, tomosynthesis, and CT for chest imaging across 59 adult patients. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2013 Jun 3;8668.

Published In

Progress in Biomedical Optics and Imaging - Proceedings of SPIE

DOI

ISSN

1605-7422

Publication Date

June 3, 2013

Volume

8668