Skip to main content
Journal cover image

Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers.

Publication ,  Journal Article
Dubowitz, G; Breyer, K; Lipnick, M; Sall, JW; Feiner, J; Ikeda, K; MacLeod, DB; Bickler, PE
Published in: Anaesthesia
December 2013

Pulse oximetry is a standard of care during anaesthesia in high-income countries. However, 70% of operating environments in low- and middle-income countries have no pulse oximeter. The 'Lifebox' oximetry project set out to bridge this gap with an inexpensive oximeter meeting CE (European Conformity) and ISO (International Organization for Standardization) standards. To date, there are no performance-specific accuracy data on this instrument. The aim of this study was to establish whether the Lifebox pulse oximeter provides clinically reliable haemoglobin oxygen saturation (Sp O2 ) readings meeting USA Food and Drug Administration 510(k) standards. Using healthy volunteers, inspired oxygen fraction was adjusted to produce arterial haemoglobin oxygen saturation (Sa O2 ) readings between 71% and 100% measured with a multi-wavelength oximeter. Lifebox accuracy was expressed using bias (Sp O2 - Sa O2 ), precision (SD of the bias) and the root mean square error (Arms). Simultaneous readings of Sa O2 and Sp O2 in 57 subjects showed a mean (SD) bias of -0.41% (2.28%) and Arms 2.31%. The Lifebox pulse oximeter meets current USA Food and Drug Administration standards for accuracy, thus representing an inexpensive solution for patient monitoring without compromising standards.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Anaesthesia

DOI

EISSN

1365-2044

Publication Date

December 2013

Volume

68

Issue

12

Start / End Page

1220 / 1223

Location

England

Related Subject Headings

  • Reproducibility of Results
  • Oximetry
  • Monitoring, Physiologic
  • Male
  • Hypoxia
  • Humans
  • Healthy Volunteers
  • Female
  • Anesthesiology
  • Adult
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Dubowitz, G., Breyer, K., Lipnick, M., Sall, J. W., Feiner, J., Ikeda, K., … Bickler, P. E. (2013). Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers. Anaesthesia, 68(12), 1220–1223. https://doi.org/10.1111/anae.12382
Dubowitz, G., K. Breyer, M. Lipnick, J. W. Sall, J. Feiner, K. Ikeda, D. B. MacLeod, and P. E. Bickler. “Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers.Anaesthesia 68, no. 12 (December 2013): 1220–23. https://doi.org/10.1111/anae.12382.
Dubowitz G, Breyer K, Lipnick M, Sall JW, Feiner J, Ikeda K, et al. Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers. Anaesthesia. 2013 Dec;68(12):1220–3.
Dubowitz, G., et al. “Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers.Anaesthesia, vol. 68, no. 12, Dec. 2013, pp. 1220–23. Pubmed, doi:10.1111/anae.12382.
Dubowitz G, Breyer K, Lipnick M, Sall JW, Feiner J, Ikeda K, MacLeod DB, Bickler PE. Accuracy of the Lifebox pulse oximeter during hypoxia in healthy volunteers. Anaesthesia. 2013 Dec;68(12):1220–1223.
Journal cover image

Published In

Anaesthesia

DOI

EISSN

1365-2044

Publication Date

December 2013

Volume

68

Issue

12

Start / End Page

1220 / 1223

Location

England

Related Subject Headings

  • Reproducibility of Results
  • Oximetry
  • Monitoring, Physiologic
  • Male
  • Hypoxia
  • Humans
  • Healthy Volunteers
  • Female
  • Anesthesiology
  • Adult