Performance of a multianode straw tube detector
Publication
, Journal Article
Oh, SH; Tepera, B; Wang, C
Published in: Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
July 27, 2015
Abstract We report on the performance of a multianode straw tube detector using cosmic rays. It is constructed inside a 5 cm diameter straw tube with twelve anode wires. A calibration technique and track reconstruction algorithm is developed for this type of detector, and we calculate the resolution from the residual distribution and show that ∼170 μm resolution is not difficult to achieve. The technique is general and especially useful for detectors with complex electric fields with or without the magnetic field.
Duke Scholars
Published In
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
DOI
ISSN
0168-9002
Publication Date
July 27, 2015
Volume
797
Start / End Page
285 / 289
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
- 0201 Astronomical and Space Sciences
Citation
APA
Chicago
ICMJE
MLA
NLM
Oh, S. H., Tepera, B., & Wang, C. (2015). Performance of a multianode straw tube detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 797, 285–289. https://doi.org/10.1016/j.nima.2015.06.052
Oh, S. H., B. Tepera, and C. Wang. “Performance of a multianode straw tube detector.” Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment 797 (July 27, 2015): 285–89. https://doi.org/10.1016/j.nima.2015.06.052.
Oh SH, Tepera B, Wang C. Performance of a multianode straw tube detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2015 Jul 27;797:285–9.
Oh, S. H., et al. “Performance of a multianode straw tube detector.” Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, vol. 797, July 2015, pp. 285–89. Scopus, doi:10.1016/j.nima.2015.06.052.
Oh SH, Tepera B, Wang C. Performance of a multianode straw tube detector. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 2015 Jul 27;797:285–289.
Published In
Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
DOI
ISSN
0168-9002
Publication Date
July 27, 2015
Volume
797
Start / End Page
285 / 289
Related Subject Headings
- Nuclear & Particles Physics
- 5106 Nuclear and plasma physics
- 0299 Other Physical Sciences
- 0202 Atomic, Molecular, Nuclear, Particle and Plasma Physics
- 0201 Astronomical and Space Sciences