Skip to main content

Status of radiation protection in various interventional cardiology procedures in the Asia Pacific region.

Publication ,  Journal Article
Tsapaki, V; Faruque Ghulam, M; Lim, ST; Ngo Minh, H; Nwe, N; Sharma, A; Sim, K-H; Srimahachota, S; Rehani, MM
Published in: Heart Asia
2011

OBJECTIVE: Increasing use of interventional procedures in cardiology with unknown levels of radiation protection in many countries of Asia-Pacific region necessitates the need for status assessment. The study was part of an International Atomic Energy Agency (IAEA) project for achieving improved radiation protection in interventional cardiology (IC) in developing countries. DESIGN: The survey covers 18 cardiac catheterisation laboratories in seven countries (Bangladesh, India, Malaysia, Myanmar, Singapore, Thailand and Vietnam). An important step was the creation of the 'Asian network of Cardiologists in Radiation Protection' and a newsletter. Data were collected on: radiation protection tools, number of IC laboratories, and annual number of various IC paediatric and adult procedures in the hospital and in the country. Patient radiation dose data were collected in terms of Kerma Area Product (KAP) and cumulative dose (CD). RESULTS: It is encouraging that protection devices for staff are largely used in the routine practice. Only 39% of the angiographic machines were equipped with a KAP meter. Operators' initial lack of awareness on radiation-protection optimisation improved significantly after participation in IAEA radiation-protection training. Only two out of five countries reporting patient percutaneous coronary intervention radiation-dose data were fully within the international guidance levels. Data from 51 patients who underwent multiple therapeutic procedures (median 2-3) indicated a total KAP reaching 995 Gy.cm(2) (range 10.1-995) and CD 15.1 Gy (range 0.4-15.1), stressing the importance of dose monitoring and optimisation. CONCLUSIONS: There is a need for interventional cardiology societies to play an active role in training actions and implementation of radiation protection.

Duke Scholars

Published In

Heart Asia

DOI

ISSN

1759-1104

Publication Date

2011

Volume

3

Issue

1

Start / End Page

16 / 24

Location

England

Related Subject Headings

  • 3201 Cardiovascular medicine and haematology
  • 1102 Cardiorespiratory Medicine and Haematology
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Tsapaki, V., Faruque Ghulam, M., Lim, S. T., Ngo Minh, H., Nwe, N., Sharma, A., … Rehani, M. M. (2011). Status of radiation protection in various interventional cardiology procedures in the Asia Pacific region. Heart Asia, 3(1), 16–24. https://doi.org/10.1136/ha.2009.001180
Tsapaki, Virginia, Mohammed Faruque Ghulam, Soo Teik Lim, Hung Ngo Minh, Nwe Nwe, Anil Sharma, Kui-Hian Sim, Suphot Srimahachota, and Madan Mohan Rehani. “Status of radiation protection in various interventional cardiology procedures in the Asia Pacific region.Heart Asia 3, no. 1 (2011): 16–24. https://doi.org/10.1136/ha.2009.001180.
Tsapaki V, Faruque Ghulam M, Lim ST, Ngo Minh H, Nwe N, Sharma A, et al. Status of radiation protection in various interventional cardiology procedures in the Asia Pacific region. Heart Asia. 2011;3(1):16–24.
Tsapaki, Virginia, et al. “Status of radiation protection in various interventional cardiology procedures in the Asia Pacific region.Heart Asia, vol. 3, no. 1, 2011, pp. 16–24. Pubmed, doi:10.1136/ha.2009.001180.
Tsapaki V, Faruque Ghulam M, Lim ST, Ngo Minh H, Nwe N, Sharma A, Sim K-H, Srimahachota S, Rehani MM. Status of radiation protection in various interventional cardiology procedures in the Asia Pacific region. Heart Asia. 2011;3(1):16–24.

Published In

Heart Asia

DOI

ISSN

1759-1104

Publication Date

2011

Volume

3

Issue

1

Start / End Page

16 / 24

Location

England

Related Subject Headings

  • 3201 Cardiovascular medicine and haematology
  • 1102 Cardiorespiratory Medicine and Haematology