MACULAR PSEUDO-HOLE IN SHAKEN BABY SYNDROME: UNDERSCORING THE UTILITY OF OPTICAL COHERENCE TOMOGRAPHY UNDER ANESTHESIA.
Journal articles
- Journal Article
Seider, MI; Tran-Viet, D; Toth, CA
Published in: Retin Cases Brief Rep
2016
PURPOSE: To describe a case of vitrectomy for nonclearing vitreous hemorrhage in shaken baby syndrome and the utility of intraoperative hand-held optical coherence tomography to distinguish a macular hole from a pseudo-hole. METHODS: Case report of a 4-month-old girl. RESULTS: After clearing of media opacity by vitrectomy, an apparent macular hole was seen with the operating microscope. However, this was shown to be only a pseudo-hole by intraoperative hand-held optical coherence tomography, requiring no further treatment. CONCLUSION: Intraoperative hand-held optical coherence tomography may be important when performing vitrectomy for nonclearing vitreous hemorrhage in shaken baby syndrome.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
Retin Cases Brief Rep
DOI
EISSN
1937-1578
Publication Date
2016
Volume
10
Issue
3
Start / End Page
283 / 285
Location
United States
Related Subject Headings
- Vitreous Hemorrhage
- Vitrectomy
- Tomography, Optical Coherence
- Shaken Baby Syndrome
- Retinal Perforations
- Point-of-Care Systems
- Infant
- Humans
- Female
- 3212 Ophthalmology and optometry
Citation
APA
Chicago
ICMJE
MLA
NLM
Seider, M. I., Tran-Viet, D., & Toth, C. A. (2016). MACULAR PSEUDO-HOLE IN SHAKEN BABY SYNDROME: UNDERSCORING THE UTILITY OF OPTICAL COHERENCE TOMOGRAPHY UNDER ANESTHESIA. Retin Cases Brief Rep, 10(3), 283–285. https://doi.org/10.1097/ICB.0000000000000251
Seider, Michael I., Du Tran-Viet, and Cynthia A. Toth. “MACULAR PSEUDO-HOLE IN SHAKEN BABY SYNDROME: UNDERSCORING THE UTILITY OF OPTICAL COHERENCE TOMOGRAPHY UNDER ANESTHESIA.” Retin Cases Brief Rep 10, no. 3 (2016): 283–85. https://doi.org/10.1097/ICB.0000000000000251.
Seider MI, Tran-Viet D, Toth CA. MACULAR PSEUDO-HOLE IN SHAKEN BABY SYNDROME: UNDERSCORING THE UTILITY OF OPTICAL COHERENCE TOMOGRAPHY UNDER ANESTHESIA. Retin Cases Brief Rep. 2016;10(3):283–5.
Seider, Michael I., et al. “MACULAR PSEUDO-HOLE IN SHAKEN BABY SYNDROME: UNDERSCORING THE UTILITY OF OPTICAL COHERENCE TOMOGRAPHY UNDER ANESTHESIA.” Retin Cases Brief Rep, vol. 10, no. 3, 2016, pp. 283–85. Pubmed, doi:10.1097/ICB.0000000000000251.
Seider MI, Tran-Viet D, Toth CA. MACULAR PSEUDO-HOLE IN SHAKEN BABY SYNDROME: UNDERSCORING THE UTILITY OF OPTICAL COHERENCE TOMOGRAPHY UNDER ANESTHESIA. Retin Cases Brief Rep. 2016;10(3):283–285.
Published In
Retin Cases Brief Rep
DOI
EISSN
1937-1578
Publication Date
2016
Volume
10
Issue
3
Start / End Page
283 / 285
Location
United States
Related Subject Headings
- Vitreous Hemorrhage
- Vitrectomy
- Tomography, Optical Coherence
- Shaken Baby Syndrome
- Retinal Perforations
- Point-of-Care Systems
- Infant
- Humans
- Female
- 3212 Ophthalmology and optometry