Determination of chromium in human lung fibroblast cells using a large bore-direct injection high-efficiency nebulizer with inductively coupled plasma mass spectrometry

Publication ,  Journal Article
McLean, JA; Acon, BW; Montaser, A; Singh, J; Pritchard, DE; Patierno, SR
Published in: Applied Spectroscopy
January 1, 2000

A novel method for the determination of chromium in suspensions of human lung fibroblast cells is described by using a large bore-direct injection high efficiency nebulizer (LB-DIHEN) with micro scale flow injection analysis and inductively coupled plasma mass spectrometric detection. Chromium(VI)-treated cells were first counted and then suspended in a phosphate buffer saline solution. With the use of the method of standard additions, the relative concentration of Cr in approx. 100 HLF cells/peak was determined at m/z = 50. Because the cells tend to clump and can yield inhomogeneities in the total number analyzed, Mg was used as an internal standard to compensate for the total cell mass. The level of Cr in HLF cells grown in a medium of 100 μM Na2CrO4 for two hours is on the order of 180 fg Cr/cell after correction for the number of cells in each injection.

Duke Scholars

Published In

Applied Spectroscopy

DOI

ISSN

0003-7028

Publication Date

January 1, 2000

Volume

54

Issue

5

Start / End Page

659 / 663

Related Subject Headings

  • Analytical Chemistry
  • 0913 Mechanical Engineering
  • 0306 Physical Chemistry (incl. Structural)
  • 0301 Analytical Chemistry
 

Citation

APA
Chicago
ICMJE
MLA
NLM
McLean, J. A., Acon, B. W., Montaser, A., Singh, J., Pritchard, D. E., & Patierno, S. R. (2000). Determination of chromium in human lung fibroblast cells using a large bore-direct injection high-efficiency nebulizer with inductively coupled plasma mass spectrometry. Applied Spectroscopy, 54(5), 659–663. https://doi.org/10.1366/0003702001950120
McLean, J. A., B. W. Acon, A. Montaser, J. Singh, D. E. Pritchard, and S. R. Patierno. “Determination of chromium in human lung fibroblast cells using a large bore-direct injection high-efficiency nebulizer with inductively coupled plasma mass spectrometry.” Applied Spectroscopy 54, no. 5 (January 1, 2000): 659–63. https://doi.org/10.1366/0003702001950120.
McLean JA, Acon BW, Montaser A, Singh J, Pritchard DE, Patierno SR. Determination of chromium in human lung fibroblast cells using a large bore-direct injection high-efficiency nebulizer with inductively coupled plasma mass spectrometry. Applied Spectroscopy. 2000 Jan 1;54(5):659–63.
McLean, J. A., et al. “Determination of chromium in human lung fibroblast cells using a large bore-direct injection high-efficiency nebulizer with inductively coupled plasma mass spectrometry.” Applied Spectroscopy, vol. 54, no. 5, Jan. 2000, pp. 659–63. Scopus, doi:10.1366/0003702001950120.
McLean JA, Acon BW, Montaser A, Singh J, Pritchard DE, Patierno SR. Determination of chromium in human lung fibroblast cells using a large bore-direct injection high-efficiency nebulizer with inductively coupled plasma mass spectrometry. Applied Spectroscopy. 2000 Jan 1;54(5):659–663.
Journal cover image

Published In

Applied Spectroscopy

DOI

ISSN

0003-7028

Publication Date

January 1, 2000

Volume

54

Issue

5

Start / End Page

659 / 663

Related Subject Headings

  • Analytical Chemistry
  • 0913 Mechanical Engineering
  • 0306 Physical Chemistry (incl. Structural)
  • 0301 Analytical Chemistry