Skip to main content

Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.

Publication ,  Journal Article
Samad, Z; Minter, S; Armour, A; Tinnemore, A; Sivak, JA; Sedberry, B; Strub, K; Horan, SM; Harrison, JK; Kisslo, J; Douglas, PS; Velazquez, EJ
Published in: Circ Cardiovasc Imaging
March 2016

BACKGROUND: The management of aortic stenosis rests on accurate echocardiographic diagnosis. Hence, it was chosen as a test case to examine the utility of continuous quality improvement (CQI) approaches to increase echocardiographic data accuracy and reliability. A novel, multistep CQI program was designed and prospectively used to investigate whether it could minimize the difference in aortic valve mean gradients reported by echocardiography when compared with cardiac catheterization. METHODS AND RESULTS: The Duke Echo Laboratory compiled a multidisciplinary CQI team including 4 senior sonographers and MD faculty to develop a mapped CQI process that incorporated Intersocietal Accreditation Commission standards. Quarterly, the CQI team reviewed all moderate- or greater-severity aortic stenosis echocardiography studies with concomitant catheterization data, and deidentified individual and group results were shared at meetings attended by cardiologists and sonographers. After review of 2011 data, the CQI team proposed specific amendments implemented over 2012: the use of nontraditional imaging and Doppler windows as well as evaluation of aortic gradients by a second sonographer. The primary outcome measure was agreement between catheterization- and echocardiography-derived mean gradients calculated by using the coverage probability index with a prespecified acceptable echocardiography-catheterization difference of <10 mm Hg in mean gradient. Between January 2011 and January 2014, 2093 echocardiograms reported moderate or greater aortic stenosis. Among cases with available catheterization data pre- and post-CQI, the coverage probability index increased from 54% to 70% (P=0.03; 98 cases, year 2011; 70 cases, year 2013). The proportion of patients referred for invasive valve hemodynamics decreased from 47% pre-CQI to 19% post-CQI (P<0.001). CONCLUSIONS: A laboratory practice pattern that was amenable to reform was identified, and a multistep modification was designed and implemented that produced clinically valuable performance improvements. The new protocol improved aortic stenosis mean gradient agreement between echocardiography and catheterization and was associated with a measurable decrease in referrals of patients for invasive studies.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Circ Cardiovasc Imaging

DOI

EISSN

1942-0080

Publication Date

March 2016

Volume

9

Issue

3

Location

United States

Related Subject Headings

  • Workflow
  • Severity of Illness Index
  • Reproducibility of Results
  • Quality Indicators, Health Care
  • Quality Improvement
  • Prospective Studies
  • Program Evaluation
  • Predictive Value of Tests
  • Practice Patterns, Physicians'
  • Patient Care Team
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Samad, Z., Minter, S., Armour, A., Tinnemore, A., Sivak, J. A., Sedberry, B., … Velazquez, E. J. (2016). Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis. Circ Cardiovasc Imaging, 9(3). https://doi.org/10.1161/CIRCIMAGING.115.003708
Samad, Zainab, Stephanie Minter, Alicia Armour, Amanda Tinnemore, Joseph A. Sivak, Brenda Sedberry, Karen Strub, et al. “Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.Circ Cardiovasc Imaging 9, no. 3 (March 2016). https://doi.org/10.1161/CIRCIMAGING.115.003708.
Samad Z, Minter S, Armour A, Tinnemore A, Sivak JA, Sedberry B, et al. Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis. Circ Cardiovasc Imaging. 2016 Mar;9(3).
Samad, Zainab, et al. “Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis.Circ Cardiovasc Imaging, vol. 9, no. 3, Mar. 2016. Pubmed, doi:10.1161/CIRCIMAGING.115.003708.
Samad Z, Minter S, Armour A, Tinnemore A, Sivak JA, Sedberry B, Strub K, Horan SM, Harrison JK, Kisslo J, Douglas PS, Velazquez EJ. Implementing a Continuous Quality Improvement Program in a High-Volume Clinical Echocardiography Laboratory: Improving Care for Patients With Aortic Stenosis. Circ Cardiovasc Imaging. 2016 Mar;9(3).

Published In

Circ Cardiovasc Imaging

DOI

EISSN

1942-0080

Publication Date

March 2016

Volume

9

Issue

3

Location

United States

Related Subject Headings

  • Workflow
  • Severity of Illness Index
  • Reproducibility of Results
  • Quality Indicators, Health Care
  • Quality Improvement
  • Prospective Studies
  • Program Evaluation
  • Predictive Value of Tests
  • Practice Patterns, Physicians'
  • Patient Care Team