Skip to main content

Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation.

Publication ,  Journal Article
Zhang, HK; Cheng, A; Bottenus, N; Guo, X; Trahey, GE; Boctor, EM
Published in: Journal of medical imaging (Bellingham, Wash.)
April 2016

Ultrasonography is a widely used imaging modality to visualize anatomical structures due to its low cost and ease of use; however, it is challenging to acquire acceptable image quality in deep tissue. Synthetic aperture (SA) is a technique used to increase image resolution by synthesizing information from multiple subapertures, but the resolution improvement is limited by the physical size of the array transducer. With a large F-number, it is difficult to achieve high resolution in deep regions without extending the effective aperture size. We propose a method to extend the available aperture size for SA-called synthetic tracked aperture ultrasound (STRATUS) imaging-by sweeping an ultrasound transducer while tracking its orientation and location. Tracking information of the ultrasound probe is used to synthesize the signals received at different positions. Considering the practical implementation, we estimated the effect of tracking and ultrasound calibration error to the quality of the final beamformed image through simulation. In addition, to experimentally validate this approach, a 6 degree-of-freedom robot arm was used as a mechanical tracker to hold an ultrasound transducer and to apply in-plane lateral translational motion. Results indicate that STRATUS imaging with robotic tracking has the potential to improve ultrasound image quality.

Duke Scholars

Altmetric Attention Stats
Dimensions Citation Stats

Published In

Journal of medical imaging (Bellingham, Wash.)

DOI

EISSN

2329-4310

ISSN

2329-4302

Publication Date

April 2016

Volume

3

Issue

2

Start / End Page

027001

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Zhang, H. K., Cheng, A., Bottenus, N., Guo, X., Trahey, G. E., & Boctor, E. M. (2016). Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation. Journal of Medical Imaging (Bellingham, Wash.), 3(2), 027001. https://doi.org/10.1117/1.jmi.3.2.027001
Zhang, Haichong K., Alexis Cheng, Nick Bottenus, Xiaoyu Guo, Gregg E. Trahey, and Emad M. Boctor. “Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation.Journal of Medical Imaging (Bellingham, Wash.) 3, no. 2 (April 2016): 027001. https://doi.org/10.1117/1.jmi.3.2.027001.
Zhang HK, Cheng A, Bottenus N, Guo X, Trahey GE, Boctor EM. Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation. Journal of medical imaging (Bellingham, Wash). 2016 Apr;3(2):027001.
Zhang, Haichong K., et al. “Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation.Journal of Medical Imaging (Bellingham, Wash.), vol. 3, no. 2, Apr. 2016, p. 027001. Epmc, doi:10.1117/1.jmi.3.2.027001.
Zhang HK, Cheng A, Bottenus N, Guo X, Trahey GE, Boctor EM. Synthetic tracked aperture ultrasound imaging: design, simulation, and experimental evaluation. Journal of medical imaging (Bellingham, Wash). 2016 Apr;3(2):027001.

Published In

Journal of medical imaging (Bellingham, Wash.)

DOI

EISSN

2329-4310

ISSN

2329-4302

Publication Date

April 2016

Volume

3

Issue

2

Start / End Page

027001

Related Subject Headings

  • 4003 Biomedical engineering
  • 3202 Clinical sciences