Skip to main content
Journal cover image

Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus.

Publication ,  Journal Article
Winemaker, MJ; Amendola, A
Published in: Foot Ankle Int
October 1996

A retrospective review of the medical records and radiographs of 32 consecutive patients, totaling 52 extremities with chevron osteotomies for hallux valgus, was conducted to compare K wire fixation with absorbable (poly-p-dioxanone) pin fixation. Each group comprised 21 feet, with a mean clinical follow-up of 35.6 months (25.6-50.5 months) in the K wire group and 23.1 months (13.7-28.8 months) in the absorbable pin group. Demographics as well as final clinical follow-up scores (hallux-metatarsophalangeal-interphalangeal scale and visual analogue scores) were similar in both groups. Postoperative hallux valgus and intermetatarsal angles were similar in both groups. No complications, such as osteolysis for inflammatory sinus formation, occurred in the absorbable pin group. Two patients in the K wire group had a malunited osteotomy and two patients had a retained K wire at final follow-up. Our experience suggests that poly-p-dioxanone pins are at least as effective as K wires, and the previous reports of inflammatory sinus formation and osteolysis are not a significant concern in the fixation of chevron osteotomies for hallux valgus.

Duke Scholars

Published In

Foot Ankle Int

DOI

ISSN

1071-1007

Publication Date

October 1996

Volume

17

Issue

10

Start / End Page

623 / 628

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Radiography
  • Postoperative Complications
  • Polydioxanone
  • Osteotomy
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
  • Hallux Valgus
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Winemaker, M. J., & Amendola, A. (1996). Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus. Foot Ankle Int, 17(10), 623–628. https://doi.org/10.1177/107110079601701007
Winemaker, M. J., and A. Amendola. “Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus.Foot Ankle Int 17, no. 10 (October 1996): 623–28. https://doi.org/10.1177/107110079601701007.
Winemaker, M. J., and A. Amendola. “Comparison of bioabsorbable pins and Kirschner wires in the fixation of chevron osteotomies for hallux valgus.Foot Ankle Int, vol. 17, no. 10, Oct. 1996, pp. 623–28. Pubmed, doi:10.1177/107110079601701007.
Journal cover image

Published In

Foot Ankle Int

DOI

ISSN

1071-1007

Publication Date

October 1996

Volume

17

Issue

10

Start / End Page

623 / 628

Location

United States

Related Subject Headings

  • Retrospective Studies
  • Radiography
  • Postoperative Complications
  • Polydioxanone
  • Osteotomy
  • Orthopedics
  • Middle Aged
  • Male
  • Humans
  • Hallux Valgus