Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society.

Publication ,  Journal Article
Schalock, PC; Crawford, G; Nedorost, S; Scheinman, PL; Atwater, AR; Mowad, C; Brod, B; Ehrlich, A; Watsky, KL; Sasseville, D; Silvestri, D ...
Published in: Dermatitis
2016

The American Contact Dermatitis Society recognizes the interest in the evaluation and management of metal hypersensitivity reactions. Given the paucity of robust evidence with which to guide our practices, we provide reasonable evidence and expert opinion-based guidelines for clinicians with regard to metal hypersensitivity reaction testing and patient management. Routine preoperative evaluation in individuals with no history of adverse cutaneous reactions to metals or history of previous implant-related adverse events is not necessary. Patients with a clear self-reported history of metal reactions should be evaluated by patch testing before device implant. Patch testing is only 1 element in the assessment of causation in those with postimplantation morbidity. Metal exposure from the implanted device can cause sensitization, but a positive metal test does not prove symptom causality. The decision to replace an implanted device must include an assessment of all clinical factors and a thorough risk-benefit analysis by the treating physician(s) and patient.

Duke Scholars

Published In

Dermatitis

DOI

EISSN

2162-5220

Publication Date

2016

Volume

27

Issue

5

Start / End Page

241 / 247

Location

United States

Related Subject Headings

  • Societies, Medical
  • Prostheses and Implants
  • Patch Tests
  • Metals
  • Humans
  • Dermatology & Venereal Diseases
  • Dermatitis, Allergic Contact
  • 3204 Immunology
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Schalock, P. C., Crawford, G., Nedorost, S., Scheinman, P. L., Atwater, A. R., Mowad, C., … DeKoven, J. (2016). Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society. Dermatitis, 27(5), 241–247. https://doi.org/10.1097/DER.0000000000000210
Schalock, Peter C., Glen Crawford, Susan Nedorost, Pamela L. Scheinman, Amber Reck Atwater, Christen Mowad, Bruce Brod, et al. “Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society.Dermatitis 27, no. 5 (2016): 241–47. https://doi.org/10.1097/DER.0000000000000210.
Schalock PC, Crawford G, Nedorost S, Scheinman PL, Atwater AR, Mowad C, et al. Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society. Dermatitis. 2016;27(5):241–7.
Schalock, Peter C., et al. “Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society.Dermatitis, vol. 27, no. 5, 2016, pp. 241–47. Pubmed, doi:10.1097/DER.0000000000000210.
Schalock PC, Crawford G, Nedorost S, Scheinman PL, Atwater AR, Mowad C, Brod B, Ehrlich A, Watsky KL, Sasseville D, Silvestri D, Worobec SM, Elliott JF, Honari G, Powell DL, Taylor J, DeKoven J. Patch Testing for Evaluation of Hypersensitivity to Implanted Metal Devices: A Perspective From the American Contact Dermatitis Society. Dermatitis. 2016;27(5):241–247.

Published In

Dermatitis

DOI

EISSN

2162-5220

Publication Date

2016

Volume

27

Issue

5

Start / End Page

241 / 247

Location

United States

Related Subject Headings

  • Societies, Medical
  • Prostheses and Implants
  • Patch Tests
  • Metals
  • Humans
  • Dermatology & Venereal Diseases
  • Dermatitis, Allergic Contact
  • 3204 Immunology
  • 3202 Clinical sciences
  • 1103 Clinical Sciences