Lens image registration for cataract detection
Publication
, Conference
Li, H; Gao, X; Tan, MH; Chow, YC; Lim, JH; Sun, Y; Cheung, CC; Wong, TY
Published in: Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011
September 5, 2011
Cataract is the leading cause of blindness worldwide. In this paper, registration of retroillumination image is investigated for detection of cortical and posterior subcapsular cataract (PSC). The pupil region is detected by local entropy filtering. The anterior image and posterior image are registered using maximum normalized cross-correlation. The registration of anterior and posterior image can be used to detect opacity in the future. The proposed algorithms were tested using clinical data and the experimental results indicate that the proposed method could facilitate automatic cataract diagnosis. © 2011 IEEE.
Duke Scholars
Published In
Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011
DOI
Publication Date
September 5, 2011
Start / End Page
132 / 135
Citation
APA
Chicago
ICMJE
MLA
NLM
Li, H., Gao, X., Tan, M. H., Chow, Y. C., Lim, J. H., Sun, Y., … Wong, T. Y. (2011). Lens image registration for cataract detection. In Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011 (pp. 132–135). https://doi.org/10.1109/ICIEA.2011.5975564
Li, H., X. Gao, M. H. Tan, Y. C. Chow, J. H. Lim, Y. Sun, C. C. Cheung, and T. Y. Wong. “Lens image registration for cataract detection.” In Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011, 132–35, 2011. https://doi.org/10.1109/ICIEA.2011.5975564.
Li H, Gao X, Tan MH, Chow YC, Lim JH, Sun Y, et al. Lens image registration for cataract detection. In: Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011. 2011. p. 132–5.
Li, H., et al. “Lens image registration for cataract detection.” Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011, 2011, pp. 132–35. Scopus, doi:10.1109/ICIEA.2011.5975564.
Li H, Gao X, Tan MH, Chow YC, Lim JH, Sun Y, Cheung CC, Wong TY. Lens image registration for cataract detection. Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011. 2011. p. 132–135.
Published In
Proceedings of the 2011 6th IEEE Conference on Industrial Electronics and Applications, ICIEA 2011
DOI
Publication Date
September 5, 2011
Start / End Page
132 / 135