Skip to main content
Journal cover image

Determination of regional VA/Q by hyperpolarized 3He MRI.

Publication ,  Journal Article
Rizi, RR; Baumgardner, JE; Ishii, M; Spector, ZZ; Edvinsson, JM; Jalali, A; Yu, J; Itkin, M; Lipson, DA; Gefter, W
Published in: Magn Reson Med
July 2004

Alveolar ventilation/perfusion ratio (VA/Q) is a key parameter in functional imaging of the lung. Herein, regional VA/Q was calculated from regional values of alveolar partial pressure of oxygen (PAO2) measured by hyperpolarized 3He gas MRI (HP 3He MRI). Yorkshire pigs (n = 7, mean weight = 25 kg) were paralyzed and maintained under isoflurane anesthesia. Animals were placed into a birdcage coil, then transferred to the bore of a 1.5 T MRI unit. Prior to imaging, animals were manually ventilated with room air for 5 min, then a 3He gas mixture was administered during breathhold and imaging performed. PAO2 was measured based on the decay rate of 3He signal. Subjects' blood gas concentrations were measured and these values and PAO2 values entered into a system of four equations with four unknowns. Calculated VA/Q values were analyzed by preparing frequency distributions for the entire lung and compared to VA/Q frequency distributions previously established in the literature as normal using other diagnostic techniques. Distributions were consistent with those in the literature, indicating that HP 3He MRI may be an accurate, quantitative, noninvasive, and nonradioactive method for acquiring VA/Q for small regions of the lung.

Duke Scholars

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

July 2004

Volume

52

Issue

1

Start / End Page

65 / 72

Location

United States

Related Subject Headings

  • Ventilation-Perfusion Ratio
  • Swine
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Isotopes
  • Helium
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Rizi, R. R., Baumgardner, J. E., Ishii, M., Spector, Z. Z., Edvinsson, J. M., Jalali, A., … Gefter, W. (2004). Determination of regional VA/Q by hyperpolarized 3He MRI. Magn Reson Med, 52(1), 65–72. https://doi.org/10.1002/mrm.20136
Rizi, Rahim R., James E. Baumgardner, Masaru Ishii, Zebulon Z. Spector, Johan M. Edvinsson, Aman Jalali, Jiangsheng Yu, Maxim Itkin, David A. Lipson, and Warren Gefter. “Determination of regional VA/Q by hyperpolarized 3He MRI.Magn Reson Med 52, no. 1 (July 2004): 65–72. https://doi.org/10.1002/mrm.20136.
Rizi RR, Baumgardner JE, Ishii M, Spector ZZ, Edvinsson JM, Jalali A, et al. Determination of regional VA/Q by hyperpolarized 3He MRI. Magn Reson Med. 2004 Jul;52(1):65–72.
Rizi, Rahim R., et al. “Determination of regional VA/Q by hyperpolarized 3He MRI.Magn Reson Med, vol. 52, no. 1, July 2004, pp. 65–72. Pubmed, doi:10.1002/mrm.20136.
Rizi RR, Baumgardner JE, Ishii M, Spector ZZ, Edvinsson JM, Jalali A, Yu J, Itkin M, Lipson DA, Gefter W. Determination of regional VA/Q by hyperpolarized 3He MRI. Magn Reson Med. 2004 Jul;52(1):65–72.
Journal cover image

Published In

Magn Reson Med

DOI

ISSN

0740-3194

Publication Date

July 2004

Volume

52

Issue

1

Start / End Page

65 / 72

Location

United States

Related Subject Headings

  • Ventilation-Perfusion Ratio
  • Swine
  • Nuclear Medicine & Medical Imaging
  • Magnetic Resonance Imaging
  • Isotopes
  • Helium
  • Animals
  • 4003 Biomedical engineering
  • 0903 Biomedical Engineering