Skip to main content
Journal cover image

Distal femoral locking plates and the posterolateral corner.

Publication ,  Journal Article
Wittstein, JR; Watson Mayer, S; Mayer, B; Krenzel, B; Deshpande, C; Zura, R
Published in: J Knee Surg
December 2013

The purpose of this study was to evaluate the effect of minimally invasive submuscular placement of a distal femoral locking plate on the posterolateral structures of the knee. Eight fresh-frozen cadaveric knees were dissected after application of a lateral distal femoral locking plate through a minimally invasive submuscular approach. The lateral collateral ligament and popliteus tendon were identified and inspected for injury. Distances from the plate to the lateral collateral ligament and popliteus insertions were determined.Neither the lateral collateral ligament nor the popliteus tendon was disrupted by the minimally invasive submuscular application of distal femoral periarticular locking plates. The mean distances to the lateral collateral ligament and popliteus tendon insertions were 2.5 and 6.6 mm, respectively.Distal femoral locking plates can be applied in a minimally invasive manner without disrupting the posterolateral structures of the knee.

Duke Scholars

Published In

J Knee Surg

DOI

ISSN

1538-8506

Publication Date

December 2013

Volume

26

Issue

6

Start / End Page

441 / 444

Location

Germany

Related Subject Headings

  • Minimally Invasive Surgical Procedures
  • Knee Joint
  • Humans
  • Bone Plates
  • Arthroplasty
  • 3202 Clinical sciences
  • 1103 Clinical Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Wittstein, J. R., Watson Mayer, S., Mayer, B., Krenzel, B., Deshpande, C., & Zura, R. (2013). Distal femoral locking plates and the posterolateral corner. J Knee Surg, 26(6), 441–444. https://doi.org/10.1055/s-0033-1347360
Wittstein, Jocelyn Ross, Stephanie Watson Mayer, Braden Mayer, Brian Krenzel, Chetan Deshpande, and Robert Zura. “Distal femoral locking plates and the posterolateral corner.J Knee Surg 26, no. 6 (December 2013): 441–44. https://doi.org/10.1055/s-0033-1347360.
Wittstein JR, Watson Mayer S, Mayer B, Krenzel B, Deshpande C, Zura R. Distal femoral locking plates and the posterolateral corner. J Knee Surg. 2013 Dec;26(6):441–4.
Wittstein, Jocelyn Ross, et al. “Distal femoral locking plates and the posterolateral corner.J Knee Surg, vol. 26, no. 6, Dec. 2013, pp. 441–44. Pubmed, doi:10.1055/s-0033-1347360.
Wittstein JR, Watson Mayer S, Mayer B, Krenzel B, Deshpande C, Zura R. Distal femoral locking plates and the posterolateral corner. J Knee Surg. 2013 Dec;26(6):441–444.
Journal cover image

Published In

J Knee Surg

DOI

ISSN

1538-8506

Publication Date

December 2013

Volume

26

Issue

6

Start / End Page

441 / 444

Location

Germany

Related Subject Headings

  • Minimally Invasive Surgical Procedures
  • Knee Joint
  • Humans
  • Bone Plates
  • Arthroplasty
  • 3202 Clinical sciences
  • 1103 Clinical Sciences