Pitfalls and errors in measuring jitter.

Publication ,  Journal Article
Stålberg, E; Sanders, DB; Kouyoumdjian, JA
Published in: Clin Neurophysiol
November 2017

The safety factor of neuromuscular transmission can be assessed by measuring the neuromuscular jitter, which reflects the time variability of processes in the motor end-plate. Jitter is increased in any condition with disturbed end-plate function, such as myasthenic conditions and ongoing reinnervation. Jitter is increasingly being measured with concentric needle (CN) electrodes, which are more prone to artefacts than single fiber EMG recordings. The objective of this review is to identify and demonstrate pitfalls that can be seen with CN jitter measurements, made with both voluntary activation and electrical stimulation. With voluntary activation, errors are caused by poor signal quality; inappropriate time reference points on the signal; an irregular firing rate; and signals with dual latencies, i.e., "flip-flop." With electrical stimulation, additional errors result from insufficient stimulation intensity; from abrupt change in firing rate; and from axon reflexes. Many pitfalls cannot be avoided during recording and can only be detected during post-processing. It is critical to be aware of these artefacts when measuring jitter with CN electrodes.

Duke Scholars

Published In

Clin Neurophysiol

DOI

EISSN

1872-8952

Publication Date

November 2017

Volume

128

Issue

11

Start / End Page

2233 / 2241

Location

Netherlands

Related Subject Headings

  • Synaptic Transmission
  • Neuromuscular Junction Diseases
  • Neuromuscular Junction
  • Neurology & Neurosurgery
  • Myasthenia Gravis
  • Humans
  • Electromyography
  • Electrodiagnosis
  • 3209 Neurosciences
  • 17 Psychology and Cognitive Sciences
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Stålberg, E., Sanders, D. B., & Kouyoumdjian, J. A. (2017). Pitfalls and errors in measuring jitter. Clin Neurophysiol, 128(11), 2233–2241. https://doi.org/10.1016/j.clinph.2017.09.001
Stålberg, Erik, Donald B. Sanders, and João Aris Kouyoumdjian. “Pitfalls and errors in measuring jitter.Clin Neurophysiol 128, no. 11 (November 2017): 2233–41. https://doi.org/10.1016/j.clinph.2017.09.001.
Stålberg E, Sanders DB, Kouyoumdjian JA. Pitfalls and errors in measuring jitter. Clin Neurophysiol. 2017 Nov;128(11):2233–41.
Stålberg, Erik, et al. “Pitfalls and errors in measuring jitter.Clin Neurophysiol, vol. 128, no. 11, Nov. 2017, pp. 2233–41. Pubmed, doi:10.1016/j.clinph.2017.09.001.
Stålberg E, Sanders DB, Kouyoumdjian JA. Pitfalls and errors in measuring jitter. Clin Neurophysiol. 2017 Nov;128(11):2233–2241.
Journal cover image

Published In

Clin Neurophysiol

DOI

EISSN

1872-8952

Publication Date

November 2017

Volume

128

Issue

11

Start / End Page

2233 / 2241

Location

Netherlands

Related Subject Headings

  • Synaptic Transmission
  • Neuromuscular Junction Diseases
  • Neuromuscular Junction
  • Neurology & Neurosurgery
  • Myasthenia Gravis
  • Humans
  • Electromyography
  • Electrodiagnosis
  • 3209 Neurosciences
  • 17 Psychology and Cognitive Sciences