Rate of instrumentation changes on postoperative and follow-up radiographs after primary complex spinal fusion (five or more levels) for adult deformity correction.
OBJECTIVEIn the United States, healthcare expenditures have been soaring at a concerning rate. There has been an excessive use of postoperative radiographs after spine surgery and this has been a target for hospitals to reduce unnecessary costs. However, there are only limited data identifying the rate of instrumentation changes on radiographs after complex spine surgery involving ≥ 5-level fusions.METHODSThe medical records of 136 adult (≥ 18 years old) patients with spine deformity undergoing elective, primary complex spinal fusion (≥ 5 levels) for deformity correction at a major academic institution between 2010 and 2015 were reviewed. Patient demographics, comorbidities, and intra- and postoperative complication rates were collected for each patient. The authors reviewed the first 5 subsequent postoperative and follow-up radiographs, and determined whether revision of surgery was performed within 5 years postoperatively. The primary outcome investigated in this study was the rate of hardware changes on follow-up radiographs.RESULTSThe majority of patients were female, with a mean age of 53.8 ± 20.0 years and a body mass index of 27.3 ± 6.2 kg/m2 (parametric data are expressed as the mean ± SD). The median number of fusion levels was 9 (interquartile range 7-13), with a mean length of surgery of 327.8 ± 124.7 minutes and an estimated blood loss of 1312.1 ± 1269.2 ml. The mean length of hospital stay was 6.6 ± 3.9 days, with a 30-day readmission rate of 14.0%. Postoperative and follow-up change in stability on radiographs (days from operation) included: image 1 (4.6 ± 9.3 days) 0.0%; image 2 (51.7 ± 49.9 days) 3.0%; image 3 (142.1 ± 179.8 days) 5.6%; image 4 (277.3 ± 272.5 days) 11.3%; and image 5 (463.1 ± 525.9 days) 15.7%. The 3rd year after surgery had the highest rate of hardware revision (5.55%), followed by the 2nd year (4.68%), and the 1st year (4.54%).CONCLUSIONSThis study suggests that the rate of instrumentation changes on radiographs increases over time, with no changes occurring at the first postoperative image. In an era of cost-conscious healthcare, fewer orders for early radiographs after complex spinal fusions (≥ 5 levels) may not impact patient care and can reduce the overall use of healthcare resources.
Duke Scholars
Altmetric Attention Stats
Dimensions Citation Stats
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Time Factors
- Spinal Fusion
- Spinal Diseases
- Retrospective Studies
- Reoperation
- Radiography
- Postoperative Complications
- Orthopedics
- Middle Aged
- Male
Citation
Published In
DOI
EISSN
Publication Date
Volume
Issue
Start / End Page
Location
Related Subject Headings
- Time Factors
- Spinal Fusion
- Spinal Diseases
- Retrospective Studies
- Reoperation
- Radiography
- Postoperative Complications
- Orthopedics
- Middle Aged
- Male