Skip to main content

Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use.

Publication ,  Journal Article
Pauwels, R; Horner, K; Vassileva, J; Rehani, MM
Published in: Dentomaxillofac Radiol
October 2019

The objective of this paper is to provide recommendations towards the appropriate use of thyroid shielding in dental cone beam CT (CBCT). Based on current evidence of thyroid radiosensitivity, dosimetric data in the presence and absence of shielding, and a depiction of potential adverse effects of thyroid shielding, a concise set of recommendations was prepared. According to current risk models, thyroid sensitivity is particularly high at a young age, and much higher for females. In the literature, involving adult male, female and paediatric reference phantoms, the use of a tightly fitted thyroid collar with a lead-equivalent thickness of at least 0.25 mm has consistently shown a significant reduction (average: 45.9%) of the equivalent dose to the thyroid. It can therefore be recommended that thyroid shielding should be routinely used for children undergoing CBCT scanning and is recommended for adults up to the age of 50. The increase of the X-ray tube current from automatic exposure control systems due to thyroid shielding can be avoided by placing the shielding collar after acquiring the scout images. Should real-time tube current modulation be implemented in dental CBCT imaging in the future, perspectives regarding the appropriate use of shielding may change according to current trends in CT. In view of the manifestation of metal artefacts, shielding is best avoided if radiological evaluation of tissues below the lower border of the mandible is needed.

Duke Scholars

Published In

Dentomaxillofac Radiol

DOI

ISSN

0250-832X

Publication Date

October 2019

Volume

48

Issue

7

Start / End Page

20190014

Location

England

Related Subject Headings

  • Young Adult
  • Thyroid Gland
  • Thermoluminescent Dosimetry
  • Radiography, Dental
  • Radiation Protection
  • Radiation Dosage
  • Phantoms, Imaging
  • Middle Aged
  • Male
  • Humans
 

Citation

APA
Chicago
ICMJE
MLA
NLM
Pauwels, R., Horner, K., Vassileva, J., & Rehani, M. M. (2019). Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use. Dentomaxillofac Radiol, 48(7), 20190014. https://doi.org/10.1259/dmfr.20190014
Pauwels, Ruben, Keith Horner, Jenia Vassileva, and Madan M. Rehani. “Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use.Dentomaxillofac Radiol 48, no. 7 (October 2019): 20190014. https://doi.org/10.1259/dmfr.20190014.
Pauwels R, Horner K, Vassileva J, Rehani MM. Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use. Dentomaxillofac Radiol. 2019 Oct;48(7):20190014.
Pauwels, Ruben, et al. “Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use.Dentomaxillofac Radiol, vol. 48, no. 7, Oct. 2019, p. 20190014. Pubmed, doi:10.1259/dmfr.20190014.
Pauwels R, Horner K, Vassileva J, Rehani MM. Thyroid shielding in cone beam computed tomography: recommendations towards appropriate use. Dentomaxillofac Radiol. 2019 Oct;48(7):20190014.

Published In

Dentomaxillofac Radiol

DOI

ISSN

0250-832X

Publication Date

October 2019

Volume

48

Issue

7

Start / End Page

20190014

Location

England

Related Subject Headings

  • Young Adult
  • Thyroid Gland
  • Thermoluminescent Dosimetry
  • Radiography, Dental
  • Radiation Protection
  • Radiation Dosage
  • Phantoms, Imaging
  • Middle Aged
  • Male
  • Humans